Regulatory Information - UTC Fire & Security interlogix ATS1135 Hoja De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
To enter the programming menu for the ATS1135 keypads:
1.
Enter the Advanced Installer Programming menu. See
Advisor Advanced Programming Manual for more details.
2.
Press (or select) 2: Bus devices
3.
Press (or select) 2: Edit devices
4.
Press (of select) 1: RAS devices
5.
Press (or select) 0 to add a RAS device, or press (select)
1 to edit an added RAS device.
6.
When editing a RAS device, press (or select) the RAS
menu option to enter the RAS menu. The display now
shows "UTC F&S, RAS1135" followed by the version
number.
7.
Press Enter to proceed to the menu or press the menu
number followed by Enter to go to a menu item directly.
Menu 1, Access LED options
Not supported. Do not use.
Menu 2, Night light options
A dimly lit keypad backlight provides the night-light to easily
locate the keypad in dark locations (enabled by default).
Menu 3, Keypad backlight options
The keypad backlight turns on bright for night time illumination
of the key labels (enabled by default). If the keypad backlight is
not required, it may be disabled.
Menu 4, RTE (egress) control
Note:
This is an additional EN 50131 Grade 3 function.
The RAS is fitted with a request to exit (RTE) control port
(labelled IN) on the wiring connector. The OUT (open collector
terminal) may be used to control a door relay.
There are three options to choose from:
RTE Only: This option requires a simple push button to be
connected to the IN terminal. A press of the button will
release the door lock relay. Used for a quick exit from an
Area (enabled by default).
RTE Arm/Disarm: Do not use.
RTE Disabled: When the "IN" terminal is not used, it is
recommended that it be disabled.
Menu 5, Reserved
Reserved for future use.
Menu 6, Factory Defaults
This option returns all RAS settings to the factory default
condition.
Menu 7, Security Mode
Not supported. Do not use.
Menu 8, Valid Card Flash
This option enables (default setting) and disables the blue LED
flash when a valid card is badged on an ATS1135 reader.
4 / 52
Menu 9, Protocol options
Not supported. Do not use.
Menu 10, Card Beep Options
This option enables the beep sounded when a card is badged
on the reader (default setting) and disables the beep.
Menu 11, Option Card
Not supported. Do not use.
Menu 12, Last Card
This option displays the number of the last card badged on an
ATS1135 reader, in the format: Facility Code/System Code, ID
Number or as raw card data (depends on setting of security
mode).
Specifications
Supply voltage
Maximum operating current
Normal operating current
Open collector output ("OUT" terminal)
Code combinations [1]:
5 digits
10 digits
ACE type (tamper protection)
Dimensions (W x H x D)
Weight
Operating temperature
IP rating
Relative humidity
[1] Notes
When Duress functionality is enabled, 6 digits codes are required
There are no invalid code combinations
The ATS1471 / ATS1475 cards make use of a 26 bit protocol,
which makes possible usage of 67108864 different cards

Regulatory information

Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
EN 50131
EN 50131-1 System requirements
EN 50131-3 Control and indicating equipment
Security Grade 3, Environmental class II
Tested and certified by Telefication B.V.
1999/5/EC (R&TTE directive): Hereby, UTC Fire &
Security declares that this device is in compliance with
the essential requirements and other relevant
provisions of Directive 1999/5/EC.
8.5 to 14.0 V
155 mA at 13.8 V
35 mA at 13.8 V
15 V max. at 50 mA max.
100 000
10 000 000 000
B
200 x 90 x 24 mm
(7.8 x 3.5 x 0.95 in.)
350 g
−10 to 55°C (22 to 127°F)
IP30
< 95% non condensing
P/N 1077842 • REV 5.0 • ISS 03FEB12

Publicidad

Tabla de contenido
loading

Tabla de contenido