Battery Replacement - Gima KD-702 Guía De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DIRECTIONS
1. Wipe or dip thermometer probe with isopropyl rubbing alcohol to disinfect
2. Press the On/Off Button next to LCD display. A tone will sound as the screen shows
followed by last recorded temperature. After showing the self-test temperature, the thermometer is now
in the testing mode.
*Note: If the measured temperature is less than 32°C or 90°F, the LCD will display Lo, if the measured
temperature is higher than 42.9°C or 109.9°F, the LCD will display Hi.
3. Position thermometer in desired location (mouth, rectum, or armpit.)
a) Oral Use: Place thermometer under tongue as indicated by "√" position
shown in Figure 2. Close your mouth and breathe evenly through the nose
to prevent the measurement from being influenced by inhaled/exhaled air.
Normal temperature between 35.7°C and 37.3°C (96.3°F and 99.1°F)
b) Rectal Use: Lubricate silver probe tip with petroleum jelly for easy inser-
tion. Gently insert sensor approximately 1cm (less than 1/2") into rectum.
Normal temperature between 36.2°C and 37.7°C (97.2°F and 99.9°F).
c) Armpit Use: Wipe armpit dry. Place probe in armpit and keep arm pres-
sed firmly at side. From a medical viewpoint, this method will always provi-
de inaccurate readings, and should not be used if precise measurements
are required. Normal temperature between 35.2°C and 36.7°C (95.4°F and 98.1°F).
4. The degree sign flashes throughout the testing process. When flashing stops an alarm will beep for
approximately 10 seconds. The measured reading will appear on the LCD simultaneously. The displayed
temperature will not change when thermometer is removed from its testing position.
*Note: Normally the buzzes are "Bi-Bi-Bi- Bi-"; Alarm beeps more rapidly w hen temperature reaches
37.8°C (100°F) or higher ,and the buzzes are "Bi-Bi-Bi----- Bi-Bi-Bi------- Bi-Bi-Bi"
5. To prolong battery life, press the On/Off Button to turn unit off after testing is complete. If no action is
taken, the unit will automatically shut off after around10 minutes.

BATTERY REPLACEMENT

1. Replace battery when
2. Pull battery cover off as shown in Figure 3.
3. Use pointed object such as a pen to remove old battery. Discard battery lawfully. Replace with new
1.5V DC button type LR41 or SR41, UCC392, or equivalent. Be sure battery is installed with "+" polarity
facing up. (See Figure 4, 5)
4. Slide battery chamber back into place and attach cover.
Figure 3
LIMITED WARRANTY
The thermometer is guaranteed for one year from the date of purchase. If the thermometer does not fun-
ction properly due to defective components or poor workmanship, we will repair or replace it free of charge.
All components are covered by this warranty excluding the battery. The warranty does not cover damages
to your thermometer due to improper handling. To obtain warranty service, an original or copy of the sales
receipt from the original retailer is required.
Disposal of this product and used batteries should be carried out in accordance with the national
regulations for the disposal of electronic products.
Avertissement:
• Lisez entièrement les instructions avant d'utiliser le thermomètre numérique.
• Risques d'étouffement: Le capuchon et la pile du thermomètre peuvent provoquer un décès en cas
d'ingestion. Ne permettez pas aux enfants d'utiliser cet instrument sans supervision parentale.
• N'insérez pas le thermomètre dans l'oreille. Il est conçu pour des mesures orales, rectales et sous l'ais-
selle uniquement.
• Ne placez pas la pile du thermomètre près d'une source de chaleur extrême car il pourrait exploser.
• Remarque: L'utilisation du couvercle de la sonde peut provoquer un écart de 0,1°C (0,2°F) avec la tem-
pérature réelle.
• Il est conseillé de contrôler le niveau de performance tous les deux ans.
• Retirez la pile de l'instrument lorsqu'il n'est pas utilisé pendant une période prolongée.
• Les performances du thermomètre peuvent être altérées dans l'un des cas suivants:
a) Utilisation dépassant la gamme de température et d'humidité spécifiée;
b) Stockage non conforme aux exigences de gamme de température et d'humidité;
c) Choc mécanique;
d) La température du patient est inférieure à la température ambiante.
appears in the lower right corner of LCD display.
Figure 4
,
Figure 2
Figure 5