EMERGENCIES: if a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department.
Gas leaking
from
cracked/cut/burned
hose.
Gas leaking
from
LP
cylinder.
Gas leaking
from
LP
cylinder
valve.
Gas leaking
between
LP cylinder
and
regulator
connection.
Fire coming
through
control
panel.
Grease
fire or
continuous
excessive
flames
above
cooking
surface.
Troubleshooting
Burner(s) will not
light
using ignitor.
(See Electronic
ignition
Troubleshooting
also)
" Damaged
hose.
Mechanical
failure due to rusting or
mishandling.
Failure of cylinder
valve from
mishandling
or mechanical
failure.
improper installation, connection not
tight, failure of rubber seal.
" Fire in burner tube section of burner
due to blockage.
" Too much grease
buildup
in burner
area.
GAS iSSUES:
" Trying
to light wrong
burner.
Burner not engaged
with control
valve.
Obstruction
in burner.
" Turn off gas at LP cylinder
or at source on natural
gas systems.
if the hose is cracked
or cut but not burned,
simply
replace
valve!hose/regulator,
if the hose is burned,
the cause could
be
other than a faulty
valve!hose!regulator.
Discontinue
use of grill
until a plumber
or gas technician
has investigated
and
corrected
the problem.
Replace
LP cylinder.
Turn off LP cylinder
valve. Return LP cylinder
to gas supplier.
Turn off LP cylinder
valve. Remove
regulator
from
cylinder
and
visually
inspect
rubber
seal for damage.
See LP Cylinder
Leak
Test and Connecting
Regulator
to the LP Cylinder.
Turn off control
knobs and LP cylinder
valve.
Leave lid open to
allow
flames
to die down. After fire is out and grill is cold,
remove
burner
and inspect
for spider
nests or rust. See Spider
Alert and Cleaning
the Burner Assembly
sections of this Use &
Care Guide.
Turn off control
knobs and LP cylinder
valve.
Leave lid open to
allow
flames
to die down. After cooling,
clean food
particles
and excess grease
from inside firebox
area, grease
tray, and
other surfaces.
Continued on next
page.
" No gas flow.
- Vapor lock at coupling nut to LP
cylinder.
" Coupling
nut and LP cylinder
valve not
fully
connected.
ELECTRICAL
iSSUES:
" Electrode
cracked
or broken;
"sparks
at
" See instructions
on control
panel
and in Use and Care section.
" Make sure valves are positioned
inside of burner
tubes.
" Ensure burner
tubes are not obstructed
with
spider webs or other
matter.
See cleaning
section
of Use and Care.
" Make sure LP cylinder
is not empty,
if LP cylinder
is not empty,
refer to "Sudden
drop in gas flow."
" Turn off knobs and disconnect
coupling
nut from LP cylinder.
Reconnect
and retry.
" Turn the coupling
nut approximately
one-half
to three-quarters
additional
turn until solid stop. Tighten
by hand only - do not
use tools.
Replace electrode(s).
crack."
" Electrode
tip not in proper
position.
" Wire
and!or
electrode
covered with
cooking
residue.
" Wires
are loose or disconnected.
" Wires
are shorting
(sparking)
between
ignitor and electrode.
" Dead battery.
Main
Burners:
Tip of electrode
should
be pointing
toward
gas port opening
on
burner.
The distance
should
be 1/8"
to 1/4". Adjust
if necessary.
Sideburner:
Tip of electrode
should
be pointing
toward
gas port opening
on
burner, the distance
should
be 1/8"
to 3/16".
Adjust
if necessary.
Clean wire and/or
electrode
with
rubbing
alcohol
and clean
swa b.
" Reconnect
wires or replace
electrode/wire
assembly.
Replace
ignitor
wire/electrode
assembly.
" Replace with a new alkaline
battery.