SECTION V - Fire-fighting measures
5.1. Extinguishing media
Carbon dioxide, dry chemical water spray (fog) or regular foam.
5.2. Special hazards arising from the substance or mixture
Hazardous decomposition: Carbon monoxide, carbon dioxide, various hydrocarbons and trace amounts of COF2 and CF4 at temperatures above
1200° F.
5.3. Advice for fire-fighters
Vapors are heavier than air. They can travel along the ground on be moved by ventilation ant hen ignited by heat, pilot lights, open flames and
other ignition sources at locations distant from the material handling point when the material is released from the container. Never use welding
or cutting torch on the product containers (even empty) because product (even minute amounts of residue) can ignite explosively. Container is
under pressure and may rupture or explode due to pressure build up when exposed to extreme heat. Containers exposed to heat may burst
ERG Guide No.
SECTION VI - Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
Put on appropriate personal protective equipment (see section 8).
6.2. Environmental precautions
Do not allow spills to enter drains or waterways.
Use good personal hygiene practices. Wash hands before eating, drinking, smoking or using toilet. Promptly remove soiled clothing and wash
thoroughly before reuse.
6.3. Methods and material for containment and cleaning up
Spill Response: Refer to other sections of this SDS for information regarding physical and health hazards, respiratory protection, ventilation,
and personal protective equipment. Ventilate area. Absorb residue on vermiculite, floor absorbent or other absorbent material. Eliminate all
ignition sources (flames including pilot lights, forklift engines, electrical sparks and machine engines). Persons not wearing personal protective
equipment should be excluded from the spill area until clean-up has been completed. Only trained personnel in spill clean-up under 29 CFR
1910.120 should be involved with spill clean-up procedures beyond the foreseeable emergency stage. Prevent material from entering drains,
sewers, streams or other bodies of water. Prevent from spreading. If run off occurs, notify appropriate authorities as required. Pump or vacuum
spilled materials to recovery containers. Transfer contaminated soil and other materials to containers for disposal.
SECTION VII - Handling and storage
7.1. Precautions for safe handling
See section 2 for further details. - [Prevention]
7.2. Conditions for safe storage, including any incompatibilities
Storage in a cool, dry, well ventilated area. Keep out of the reach of children.
Incompatible materials: Avoid contact with strong oxidizers, sodium-potassium allow heat, and open flame.
Avoid conditions such as temperature above 1000 F.
See section 2 for further details. - [Storage]
7.3. Specific end use(s) No data available.
www.nordsonefd.com/es
espanol@nordsonefd.com
+34 963 132 243 Contamos con una red mundial de ventas y servicio para los sistemas dosificadores de Nordson EFD.
Autoválvula neumática 400