Setting Slider Tabs (built-in jumper)
Set R Slider Tab.
• Use built-in jumper (R Slider Tab)
to differentiate between one or two
transformer systems.
• If there is only one R wire, and it is
connected to the R, Rc, or RH terminal, set
the slider to the up position (1 wire).
• If there is one wire connected to the R
terminal and one wire connected to the Rc
terminal, set the slider to the down position
(2 wires).
NOTE: Slider Tab for U terminals should be left
in place for T1 Pro models.
UWP Wiring terminal designations
S
Not used for T1
thermostat.
S
Compressor contactor
Y
(stage 1)
Not used for T1
Y2
thermostat.
G
Fan Relay
24VAC common. For 2
transformer systems,
C
use common wire from
cooling transformer.
U
Not used for T1
thermostat.
U
* Terminal can be jumped using Slider Tab. See "Setting Slider Tabs" above.
L/A
Not used for T1 thermostat.
- A
Changeover Valve (TH1110D
O/B
only)
AUX -
Not used for T1 thermostat.
W2
E
Not used for T1 thermostat.
W
Heat relay (stage 1)
K
Not used for T1 thermostat.
24VAC power from heating
R
transformer*
24VAC power from cooling
Rc
transformer*
3
UWP Mounting System
R/Rc Slider Tab
(built-in jumper)
Note: Not all
terminals may be
used, depending
on the system
type that is being
wired. The most
commonly used
terminals are
shaded.