Operational Mode; User-Maintenance Instructions - Campbell Hausfeld AT0510 Manual De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATING INSTRUCTIONS
(Continued)
runs up to 50 feet. Use 3/8 inch air
hoses for 50 foot run or longer.
4. Use a pressure regulator on the
compressor, with an operating
pressure of 0 PSI - 125 PSI. A pressure
regulator is required to control
the operating pressure of the tool
between 60 PSI and 90 PSI.

OPERATIONAL MODE

To remove nuts, turn the forward/
reverse dial to the right. To install nuts,
turn the forward/reverse dial to the left.
Reverse the procedure if the threads
are left-handed. Do not overtighten the
nuts.
When tightening,
do not torque
down the nuts or bolts with the
ratchet as typically done with a
hand wrench. This can damage
the tool by breaking parts in the
ratchet mechanism.
Use of a whip
hose prevents
accidental triggering of the tool
when pressurized air is connected
to the system.
In addition, the tool's vibration wears
out quick couplers prematurely.
Using fittings or air hoses which are too
small can create a pressure drop and
reduce the power of the tool. A 3/8 inch
(I.D.) fitting with 1/4 inch NPT threads
is recommended. Most compressors
are shipped with a short, 1/4 inch I.D.
hose. For proper performance and more
convenience, use a 3/8 inch I.D. hose.
Hoses longer than 50 feet should have a
1/2 inch I.D.
NOTE: It is not recommended to install
a quick coupler between the air tool
and the leader (whip) hose.
Never carry a tool
by the hose or
pull the hose to move the tool or a
compressor. Keep hoses away from
heat, oil and sharp edges. Replace
any hose that is damaged, weak or
worn.
USER-MAINTENANCE
INSTRUCTIONS
TECHNICAL SERVICE
For information regarding the opera-
tion or repair of this product, please
visit www.campbellhausfeld.com.
TOOL REPAIR
Only qualified personnel should repair
the tool and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and accessories
which perform equivalently.
ASSEMBLY PROCEDURE FOR SEALS
When repairing a tool, the internal
parts must be cleaned and lubricated.
Parker O-lube or equivalent must be
used on all o-rings. Each o-ring must be
coated with O-lube before assembling.
A small amount of oil must be used on
all moving surfaces and pivots. After
reassembling, a few drops of 30W
non-detergent oil or equivalent, must
be added through the air line before
testing.
5
AT0510, TL0501
STORAGE
The air tool must be lubricated before
storing. Follow the air tool lubrication
instructions with an exception to step 4.
Only run the air tool for 2 to 3 seconds
instead of 7 to 10 seconds because more
oil needs to remain in the air tool when
storing.
www.campbellhausfeld.com

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Tl0501

Tabla de contenido