G G G G G Test the GSM Network signal strength
before mounting the GS3050-A in the
proposed placement.
1. Remove the screws and the metal casing [1].
2. Drill the anchor screw holes (use the back-
plate to mark the screw locations).
Check for cable conduits and water
G
pipes before drilling.
3. Lay the cables, then pull them through the ca-
ble entry [11].
4. Attach the backplate to the wall.
5. Insert the SIM-CARD (see Figure 2a).
The SIM-CARD PIN must be disabled.
G
6. Complete the connections on the terminal bo-
ard [10].
7. Fit the antenna [2] and connector [5], then clo-
se the GS3050-A.
CONNECTIONS
A detailed description of the GS3050-A terminals
can be found in Table 3.
G G G G G Use
shielded
connections, with one end connected to
negative, and the other floating.
Connect the Security device telephone terminals
(L.E. on BENTEL products) to terminals 3-4 (L.I.)
on the GS3050-A board and, if required, connect
Terminals 1-2 (L.E.) directly to the PSTN line.
1-2 [L.E.]
External telephone line.These terminals can be connected to the PSTN line.
Internal telephone line. These terminals (normally connected to the PSTN line) must
3-4 [L.I.]
be connected to the telephone device terminals (terminals L.E. on Bentel Diallers).
Earth. In compliance with the Telecommunications Network Safety Standards
5 [
]
(Overvoltage protection), this terminal must be connected to the Mains Earth.
6-14 [
]
Negative Power Supply
Programmable Open-Collector Outputs that can be activated by SMS or the
following events:
1) PSTN Trouble (O1 at default)
7-8-9-10-11
2) GSM Trouble (O2 at default)
[01]...[05]
3) COMMUNICATION Trouble between the MAIN Board and GSM Module (O3 at default)
5) OUTGOING call (O5 at default)
5) INCOMING call (O5 at default)
Tamper. These terminals must be connected to the Tamper switch: they are closed when
12-13 [A.S.]
the GS3050-A is properly closed, and will open when the frontplate is removed.
15-16-17-18
Programmable Alarm line. Activates the SMS Dialler and Telephone functions (Line
[L1]...[L4]
1 [L1] priority)
Power Supply. These terminals must be connected to a 13.8 V_ 1A min. power
19-20
supply, whereas.
[+ 12V][–]
The GS3050-A must be connected to a standby battery.
8
cable
only
for
Table 3 - TERMINALS
Table 2 - INPUT POLARITY
Activation
Command for
Input Lines
Positive
+12V
Positive
Floating/GND 0V
Negative
GND 0V
Negative
Floating/12V
(*) - The Jumper P2 (17) sets the polarity of Lines L1 and L2.
(*) - The Jumper P3 (18) isets the polarity of Lines L3 and L4.
The 5 OC Outputs refer respectively to terminals 7-
8-9-10 and 11 (O1, O2, O3, O4 and O5). These
Outputs are programmed at default to signal the even-
ts shown in Table 3. The Output signals and Standby
all
Polarity (Normally Open (â
(á
á ) can be programmed as per requirements.
á
á
á
Each OC Output can close 70 mA maximum
current to negative.
GS3050-A - GSM Dialler and Interface
Settings
Programming
Jumper
P2 - P3*
Via Software
O
á
a
O
N.C.
o
O
â
a
O
N.O.
o
o
â
b
O
N.O.
O
o
á
b
O
N.C.
O
â ) or Normally Closed
â
â
â
Manual
L
H
H
L