EGAmaster 56095 Manual De Instrucciones página 26

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Counting record: This feature counts how many times the wrench has been used, but only
counts when applying up to 60% of maximum torque. This record is not erasable until re-calibration.
The feature will count up to 65,000 measurements.
Regarding the number of measurements, the following figure means the recorded count is 10100.
(No-1 means 10000 times, No-2 means 20000 times reached and so on...)
Note:
1. If
appears, it means the wrench has been torqued to more than 110% of maximum
torque.
2. When max. operation torque has been reached, the alarm will change to a steady tone and
the green&red LED will illuminate.
26
TRACK MODE OPERATION