Minebea Intec Novego Manual De Instalación página 96

Tabla de contenido

Publicidad

11.
The marking of the equipment shall include:
IS CL I, II, III, DIV 1, GP A,B,C,D,E,F,G Entity - 4012 101 5688
NI CL I, II, III, DIV 2, GP A,B,C,D,E,F,G - 4012 101 5688; NIFW
T4A Ta= -40°C to 70°C; T5 Ta= -40°C to 55°C
12.
Description of Equipment:
General - The Model PR 62xx Series Load Cells are precision compression load cells designed to meet the
specific requirements of a wide range of weighing installations.
Construction - The Model PR 62xx Series Load Cells are contructed of welded stainless steel, hermetically
sealed, and filled with inert gas.
Ratings - The Model PR 62xx Series Load Cells are rated for an operating temperature range of -40°C to 70°C.
Entity and Nonincendive Field Wiring parameters are as defined below.
PR 62a/bc d e. Load Cell.
Entity/Nonincendive Field Wiring Parameters:
Ui = 25 V, Ii = 160 mA, Pi = 2 W; Ci= 0 μF, Li= 0 mH.
a = 01, 02, 03, 11, 12, 21, 41, 46, 51, 61
b = up to three numbers denoting the maximum capacity (may be separated by a dot)
c = Unit of measurement: blank or t
d = Accuracy: up to three numbers or letters (may be separated by dots)
e = Special: F or blank
13.
Specific Conditions of Use:
None
14.
Test and Assessment Procedure and Conditions:
This Certificate has been issued in accordance with FM Approvals US Certification Requirements.
15.
Schedule Drawings
A copy of the technical documentation has been kept by FM Approvals.
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals LLC. 1151 Boston-Providence Turnpike, Norwood, MA 02062 USA
T: +1 (1) 781 762 4300 F: +1 (1) 781 762 9375 E-mail:
F 347 (Mar 16)
SCHEDULE
US Certificate Of Conformity No: FM17US0276
information@fmapprovals.com www.fmapprovals.com
Page 2 of 3

Publicidad

Tabla de contenido
loading

Tabla de contenido