Behringer NX6000 Manual Del Usuario página 39

Ocultar thumbs Ver también para NX6000:
Tabla de contenido

Publicidad

p '
System
Inputs
Input impedance
Outputs
Output circuit type
Distortion
Frequency response
Damping factor
Signal-to-noise
USB
Rear panel USB connector type В
for remote control of DSP section
Г Circuit Protection
Cooling
Amplifier protection
Load protection
Г Power Supply, Voltage, Current Consumption (Breaker / Fuses)
USA/Canada
Japan
UK/Australia/Europe
Korea / China
Power consumption @20,
1 / e rated power
Power consumption @40,
1 / e rated power
Mains connector
Г Dimensions/Weight
Dimensions (H* x W x D)
Weight
including 5mm rubber feet
NX6000
NX6000D
2 x combo jacks
2 x locking-style professional speaker connectors
<0.2%
20 Hz to 20 kHz, +0/ -2 dB
>140@8
On/off muting, DC-fault power supply shutdown
120 V~, 60 Hz, (T 25 AH 250 V)
100 V~, 50/60 Hz, (T 25 AH 250 V)
220-240 V~, 50/60 Hz, (T 12 A H 250 V)
220-240 V~, 50/60 Hz, (T 12 AH 250 V)
620 W
94 x 483 x 316 mm (3.7 x 19.0 x 12.4")
6.0 kg (13.2 lbs)
5.9 kg (13.0 lbs)
NX4-6000
4 x combo jacks
10 kO unbalanced, 20 kO balanced
4 x locking-style professional
speaker connectors
Class D
<0.2%
<0.1%
>100 dB
Continuously variable speed fan
Back-to-front air flow
Thermal and DC protection
Stable into reactive or mismatched loads
620 W
'
620 W
Standard IEC receptacle
6.1 kg (13.4 lbs)
Quick Start Guide
39
NX3000D
2 x combo jacks
2 x locking-style professional
speaker connectors
<0.3%
20Hzto20kHz,+0/-1dB
>145 @80
Rear panel USB connector type В
for remote control of DSP section
100-120 V~, 50/60 Hz,
(T 10 AH 250 V)
100-120 V~, 50/60 Hz,
(T 10 AH 250 V)
220-240 V~, 50/60 Hz,
(T 6.3 AH 250 V)
220-240 V~, 50/60 Hz,
(T 6.3 AH 250 V)
350 W
94x483x231 mm
(3.7x19.0x9.1 " )
3.6 kg (7.9 lbs)
on
л
i

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Nx3000Nx1000Nx4-6000Nx6000dNx3000dNx1000d

Tabla de contenido