R&S
Cable Rider ZPH
– If you cannot discharge the battery, it may be deep discharged. Charge the
battery for 0.5 hours and check again.
– If you cannot charge the battery, it may be overcharged. Discharge the
battery and check again.
– If the battery has been short-circuited, charge it to reset the electronics.
– If the battery still does not work, contact the Rohde & Schwarz customer
support.
● Do not allow metallic objects to come into contact with the terminals.
● Do not solder directly to the battery.
3.1.6.2
Storage
The battery self-discharges while not in use. When storing the battery for an
extended period of time, make sure to
● Handle the battery carefully to avoid short circuits. Make sure that leads and
terminals are insulated.
● Keep the battery in the supplied packaging before use. The temperature
should not exceed 30°C.
● Store the battery at an initial state of charge between 15% and 50% of its
capacity. When calculating the initial state of charge, consider
– The maximum consumption of electronic devices
– The self-discharge of the battery - the higher the state of charge, the
higher the rate of self-discharge
● Avoid a deep discharge of the battery. A deep discharge occurs when the
state of charge falls below 5% of the battery's capacity.
● Recharge the battery at least every six months.
Should the battery voltage be low or even 0 V, the battery protection circuit may
have gone into a sleep mode. In that case, reset the battery with an approved
charger.
3.1.6.3
Transportation
No special regulations apply for transporting the battery. The battery cells contain
no metallic lithium.
Getting Started 1321.0944.02 ─ 04
Preparing for Use
Putting into Operation
16