5.
Close the ADF cover
ADF cover
You should hear the ADF cover click into position
when it returns to its original position.
6.
Turn on the scanner.
ScanSnap Manager icon changes from
7.
Right click the "ScanSnap Manager" icon
task tray, and select [Check consumable supplies]
from the menu.
8.
In the "Check consumable status" window, click the
[Reset] button of Pad ASSY Count.
The counter is reset to "0".
6.3. Replacing the Pick Roller
Replace the Pick roller following the procedure below.
1.
Remove the document on the Paper chute cover.
2.
Open the ADF cover while pulling the Cover open
lever.
Paper chute
cover
ADF cover
Cover open lever
3.
Remove the Sheet guide.
Pinch the handle on the Sheet guide to remove it.
4.
Rotate the Pick roller bushing (Left) in the direction
S
to
.
of the arrow.
S
on the
Pick roller
5.
Remove the Pick roller with its shaft.
Hold the left part of the shaft, and raise it to remove
the shaft from the scanner while pulling the shaft to
the left.
Pick roller shaft
ScanSnap fi-5110EOX2 Getting Started | 19
Sheet guide
Pick roller bushing
Pick roller shaft
Pick roller
If the around the pick roller is dirty by paper
-powder, it may cause a scanning error.
Please remove the dirt using a dry cloth with
dollop of Cleaner F1.
* Don't use water, mild detergent or air-spray.
Handle
Claw