Changing Back Tamper position
The back tamper is by default secured on the right
side of the internal base (rear view). If you wish to
move it to the left side (rear view), do the following
(Figure 5):
1. Remove tamper screw 1 in order to release the
tamper from position 7.
2. Ensure tamper spring 2 rests over tamper wire
base 4.
3. Ensure plastic tamper bracket 3 rests over both
2 and 4.
4. Secure tamper screw 1 into 3 over position 6.
Notes:
1. Verify that you hear a "Click" when attaching the tamper spring to the wall.
2. For pole installation, the tamper can be moved to the bottom right-hand side of the internal base.
Terminal Wiring
12VDC
FREE
ALARM
+
-
YEL
N.C
+,-
12 VDC
ALARM
N.C relay, 24VDC , 0.1A
FREE YEL
This terminal is a free pin that can be used to connect wires and EOL resistors
TAMPER
N.C switch, 24VDC , 0.1A
FREE
This terminal is a free pin that can be used to connect wires and EOL resistors
GREEN
AM
Normally closed AM relay output (
trouble in the detector (not including dust/dirty lens).
The Proximity AM enables receiving sabotage alerts before the detector is
damaged or masked, using both microwave channels.
Note:
When DIP8 is defined as Enabled this relay also opens momentarily when a Proximity
attempt occurs.
LED
Used to remotely control the LEDs when DIP1 is set to ON.
ENABLE
Enable: input is +12V OR no terminal connection
Disable: Connect the input to 0V
DUST
N.O. collector max 70 mA. Indicates that the lens is dirty and requires cleaning.
TEST
Used to perform remote alarm testing to the detector by applying 0 volts to this
terminal.
Success: Alarm relay is momentary opened.
Failure: AM relay is opened
SET/
This input enables to control Anti-masking and LEDs operation in accordance to
UNSET
the system status, Set (Arm) / Unset (Disarm).
While the system is armed this feature prevents an intruder from gaining
knowledge of the detector's status and disables Anti-masking detection.
System Status
Set (Arm)
Unset (Disarm)
* DIP7 is ON (Anti masking enabled)
** DIP1 is ON (LEDs enabled) and LEDs ENABLE input terminal is enabled
(+12V OR no terminal connection).
6
FREE
LEDs
TAMPER
AM
DUST TEST
GREEN
ENABL
N.C
WatchOUT DT - PCB
Input Status
0V
12V or no connection
WatchOUT 315DT Installation Manual
Figure 5
3
1
4
2
SET/
UNSET
) indicates Anti Masking alarm or any
24VDC, 0.1A
AM Relay
Off
On*
Left Side
Tamper
6
Right Side
LEDs
Off
On**
Tamper
7
5
AM