Diagnostics
The ProSYS enables you to test parameters that reflect the operation of the detector.
1. From the main user menu press
2. Enter the Installer code (or sub-installer) and press
3. Press [9] [1] to for the BUS Zones diagnostic menu.
4. Enter the digit of the zone that you want to test and then press
perform the diagnostics test and a list of test parameters will appear, as indicated in the table
below.
5. Use the keys
User Menu: 4) Maintenance → 9) Diagnostic → 1) BUS Zone
Quick Keys
Parameter
[4][9][1][zzz]
Detector Input Voltage: Display the input voltage of the detector.
PIR 1 Level: PIR channel 1 DC level. Range 0.1v - 4v
PIR 1 Noise Level: PIR channel 1 AC level. Range 0VAC (No noise) - 4VA
PIR 2 Level: PIR channel 2 DC level. Range 0.1v - 4v
PIR 2 Noise Level: PIR channel 2 AC level. Range 0VAC (No noise) - 4VA
MW 1 Level
MW 1 Noise Level
MW 2 Level: MW channel 2 DC level Range 0.1v - 4v
MW 2 Noise Level: MW channel 2 AC level (0VAC (No noise) - 4VAC
[4] to access the Maintenance menu.
/
/
:
MW channel 1 DC level Range 0.1v - 4v
:
MW channel 1 AC level (0VAC (No noise) - 4VAC)
WatchOUT 315DT Installation Manual
/
to view the diagnostics test results.
.
/
. The system will