Descargar Imprimir esta página

TECO 302 Serie Manual De Instrucciones página 125

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Pilot lamp (6)
Upper travel limit exclusion button (14)
Manual levelling button (15) - always be done with no load on the lift
If pressed (15) at the same time as the up button (2) below the measurement of the
maximum height travel limit, it opens the exhaust solenoid valve and permits the lift to
go up slowly.
If pressed (14 and 15) together with the up button (2) when the lift stops at the maximum
height, it passes the upper travel limit and also opens the levelling to permit cylinder
bleeding.
If pressed (15) and immediately released, together with the down button (3), it permits
the extra oil to exit from the secondary cylinders.
WARNING! It 'strictly FORBIDDEN to the leveling
of the lift with the vehicle on the lift.
6
1
Be sure the safety area is free from people and objects during the
final travel.
8.1.1 Controls lift WiTH mECHaNiCaL SaFETY DEViCES
The commands for using the lift are:
Main switch (1)
The main switch has two positions:
Position 0: the lift wiring circuit is not powered; the switch may be locked with a metal
padlock to prevent use.
Position 1: the lift wiring circuit is powered;
Up button (2)
Press the black 'up' button to raise the lift. The lift raises to the upper software limit
Operator's manual
1
2
1
1
4
1
15
1
3
1
24
14
1
UK
125

Publicidad

loading

Productos relacionados para TECO 302 Serie