Priming Menu (Continued)
c) To set the System Priming Time:
to scroll to the "System Priming Time" setting. Press the Select button
to select it. To enter additional priming time to ensure that the entire
system is fully primed, see step 4.
Any additional time required for the pool piping system to reach prime
after the pump is primed is called "System Priming Time." The "System
Priming Time" value is entered in minutes, from 0 to 5 minutes. (Default
0 minutes). Remember that the average system should prime quickly,
and that IntelliFlo has the ability to monitor itself to ensure that it is
primed. "System Priming Time" is for high volume, or complex systems
that may need additional priming time to relieve all the air from the pipes. The builder can
program a pre-determined amount of time, up to 5 minutes, to aid in relieving the air from
diffi cult fi lters or complex vertical plumbing. The "System Priming Time" should only be
used where large air traps become problems within the system. During the priming cycle
at each startup, the display will inform the user when System Priming is engaged and
when it is fi nished .
4. To change the setting, press the Left and Right arrows to select which digit to modify, then use the
Up and Down arrows to change the selected digit.
5. When you are done, press the Enter button to save the changes. To cancel any changes, press the
Escape button to exit edit mode without saving.

Filter Menu

IntelliFlo will calculate the required fl ow rate based on pool size, pool turns per day, cycles per day, and
schedule to control the pump motor speed and keep a constant fl ow. The fi lter mode can run schedules,
cycles, power saves, or features. The IntelliFlo internal scheduler will keep track of which function to
run. IntelliFlo is constantly monitoring the fi lter, when it detects that the system is dirty, it will display an
"Alert - Service System Soon" message on the control panel display. The user must then clean the fi lter by
performing a Backwash cycle
more information on backwashing).
To access the Filter menu:
1. Ensure that the green power LED is on and the pump is stopped.
2. Press the Menu button. "Pool Data" is displayed.
3. Use the Up and Down arrow buttons to fi nd the"Filter" menu item. Press the Select button to
select it.
a) To set the Clean Filter Pressure:
fi nd the "Clean Filter Pressure" setting. Press the Select button to select it. To
change the setting, see step 4 below.
This parameter can be set from 0,1 to 3,5 bar. (Default 1,0 bar). The typical
setting for most pools and fi lters is between 0,6 bar and 0,7 bar.
IntelliFlo VF Installation and User's Guide
Use the Up and Down arrow buttons