Filter Menu (Continued)
Filter Cycle Settings
The table below shows the settings available in Filter Mode.
NAME
Clean Filter
Pressure
Turnovers
Per Day
Cycles per
Day
Start Cycle 1
Stop Cycle 1
Start Cycle 2
Stop Cycle 2
Start Cycle 3
Stop Cycle 3
Start Cycle 4
Stop Cycle 4
Based on "Pool Volume", "Turnovers per day" and the total number of hours for Cycle 1 + 2 + 3 + 4
the fl ow must be calculated:
PoolVolume
"
=
Flow
+
Cycle
1
Note: Only enabled cycles are included in the calculation
VALUE
0,1 to 3,5 bar
(default 1.0 bar)
1-8 (Default 1)
1-4 Cycles (Default 1)
1:00 -12:59 HH.MM am/pm
(Default 9:00)
1:00 -12:59 HH.MM am/pm
(Default 21:00)
1:00 -12:59 HH.MM am/pm
(Default 21:10)
1:00 -12:59 HH.MM am/pm
(Default 21:20)
1:00 -12:59 HH.MM am/pm
(Default 21:30)
1:00 -12:59 HH.MM am/pm
(Default 21:40)
1:00 -12:59 HH.MM am/pm
(Default 21:50)
1:00 -12:59 HH.MM am/pm
(Default 22:00)
×
Turnovers
p r
"
"
+
+
Cycle
2
Cycle
3
Cycle
DESCRIPTION
The differential pressure from the 0-pressure to 100%
Ä lter status.
The number of times per day the volume of water
setup in "Pool Volume" will be moved.
The number of cycles (start and stop) the IntelliFlo
must do per day.
Start time for cycle 1 (if start and stop is the same
time the IntelliFlo will run 24*7).
Stop time for cycle 1 (if start and stop is the same
time the IntelliFlo will run 24*7).
Start time for cycle 2. If "Cycles per day" is below 2,
"Disabled" will be displayed.
Stop time for cycle 2. If "Cycles per day" is below 2,
"Disabled" will be displayed.
Start time for cycle 3. If "Cycles per day" is below 3,
"Disabled" will be displayed.
Stop time for cycle 3. If "Cycles per day" is below 3,
"Disabled" will be displayed.
Start time for cycle 4. If "Cycles per day" is below 4,
"Disabled" will be displayed.
Stop time for cycle 4. If "Cycles per day" is below 4,
"Disabled" will be displayed.
day
"
4
IntelliFlo VF Installation and User's Guide
29