Installation Instructions: Put the lock washer then flat
washer on the bolt and insert down through foot of unit into
the top of the dome isolator. Align isolator to match holes to
be mounted to in the rigid frame. Hole patterns can be found
to the right. After checking measurements and drilling the
hole pattern, secure unit to rigid frame using appropriately
sized bolts for your (the installer is responsible for supplying
these bolts and ensuring they are suitable for securing the
unit).
WARNING: IF UNIT IS NOT PROPERLY SECURED,
THE UNIT MAY COME LOOSE AND SUSTAIN
DAMAGE. IMPROPER SECURING OF THE UNIT
WILL VOID THE WARRANTY.
Drill holes in rigid mounting frame using the hole pattern
above matching the description of unit. Measurements can
vary slightly, check measurements with unit before drilling
holes.
GROUNDING INSTRUCTIONS
This product must be grounded. If it should malfunction or
breakdown, grounding provides a path of least resistance
for electric current to reduce the risk of electric shock.
DANGER: IMPROPER CONNECTION OF THE
EQUIPMENT GROUNDING CONDUCTOR CAN
RESULT IN A RISK OF ELECTROCUTION.
CHECK WITH A QUALIFIED ELECTRICIAN
OR SERVICE PERSON IF YOU ARE IN DOUBT
AS TO WHETHER THE UNIT IS PROPERLY
GROUNDED.
The screw and ground terminal on the frame must always
be used to connect the unit to a suitable ground source. The
ground path should be made with #8 size wire. Connect the
terminal of the ground wire between the star washers and
screw then tighten the screw fully. Connect the other end
of the wire securely to a suitable ground source.
The National Electric Code contains several practical ways
in which to establish a good ground source. Examples given
below illustrate a few of the ways in which a good ground
source may be established.
A metal underground water pipe in direct contact with
the earth for at least 10 feet can be used as a grounding
source. If a pipe is unavailable, an 8 foot length of pipe or
rod may be used as the ground source. The pipe should
be 3/4 inch trade size or larger and the outer surface must
be noncorrosive. If a steel or iron rod is used it should be
at least 5/8 inch diameter and if a nonferrous rod is used it
should be at least 1/2 inch diameter and be listed as material
for grounding. Drive the rod or pipe to a depth of 8 feet. If a
rock bottom is encountered less than 4 feet down, bury the
rod or pipe in a trench. All electrical tools and appliances
operated from this unit, must be properly grounded by use
of a third wire or be "Double Insulated".
Operator's Manual
Installation
8 GALLON UNITS: HOLE PATTERN
30 GALLON UNITS: HOLE PATTERN
3.00
19.50
20.25
FRONT
NOTE: ALL HOLES 11/32"
*DRAWING NOT TO SCALE
3.00
17