Installation
1b Backing Rough-In
Areas marked as
backing compliant with local building
codes. Anchor hardware is not provided.
For clarity, the motor assembly is not shown.
Secure the frame assembly to the wall at (4) locations marked "B"
B
using appropriate fasteners (1¼" square washers are provided). When
mounting is complete, check to ensure the frame assembly is level.
19"
(483mm)
17⁵⁄₈"
(448mm)
CODE
A
" Bowl Anchors with a Minimum Pull-Out Force of 1,000 lbs.
³⁄₈
B
" Frame Anchors
³⁄₈
VERTICAL HEIGHT ADJUSTMENTS FOR
RIM HEIGHT
34"
No Adjustment
31"
Subtract 3"
26"
Subtract 8"
32"
Subtract 2"
30"
Subtract 4"
Bradley • 215-1771 Rev. D; ECN 13-08-028
require sufficient
30"
(762mm)
⁵⁄₈" REF.
(16mm)
B
B
8¾"
(222mm)
C
DESCRIPTION
CODES A, B, H, C, D and E
Remove white laser film from end caps
prior to installation of frame to wall.
11¾"* REF.
(298mm)
A
A
B
B
15¾"
(400mm)
Finished
Floor
L
Standard
Juvenile
Junior
TAS Grades 6 through 8 or 9
TAS Grades Pre-K through 5 or 6
1/21/2014
Install wall anchors per
A
local codes at locations
shown below.
*See Step 2 before
drilling basin anchors
9½"
(241mm)
36¹⁄₈" REF.
27⁵⁄₈" REF.
(918mm)
(702mm)
20¾"
(527mm)
QTY.
FIXTURE STYLE
AV30
2
4
11