ERROR MESSAGE
The error messages are shown on the display.
Er1
The M1 motor's self-learning of the gate travel is interrupted; check whether the motor is properly connected and functioning.
The M2 motor's self-learning of the gate travel is interrupted; check whether the motor is properly connected and functioning.
Er2
Er3
Encoder is broken.
Services-test error; check whether the safety devices are properly connected and functioning.
Er4
Er5
Insuffi cient operating time; check the F22 set time, it may need extending to complete the duty cycle.
Er6
Maximum number of obstructions detected.
Overheated transformer - the gate leaves stay open after an "open" command.
Er7
CO
Contact 1-2 (STOP) unused; deactivate the contact from function F1.
C1/2/3/4
Contacts CX and/or CY unused: deactivate contacts from functions F2 and/or F3.
Flashing red LED: the control board is calibrated to the gate travel.
FINAL OPERATIONS
Once the connections and commissioning are done,
fasten the cover the control panel by using the
supplied hardware.