3.4 – ELECTRIC DRAWING AND CONTROL PANEL
REP. DESCRIPTION
14*
Valve connector
17
Salinometer cell
30
Green selector switch
31
Red selector switch
32
Discharge signal lamp
33
Production signal lamp
34
Main breaker
36
Fuse minifuse
37
Power relay KM1
41
Blue selector switch
41
31
30
14*
17
It is recommended to install the control panel near to the unit to facilitate the maintenance.
NB: it is possible to install a remote control (see following page)
J:\Etude-3d\Aquaset\0-DOSSIER TECHNIQUES\1-sw-plaisance\ESW\00-ESW 0707\09- Manuels Utilisateur\DOC UTILISATEUR ESW FRUKES 2009-10-C.doc
FONCTION
Connection of the discharge valve to the salinometer card.
Measures the salinity of the produced water with a cell.
Starting up of the unit and lighting up of the green indicator lamp.
Stopping of the unit.
Red LED indicating that the reject valve is in « discharge » position.
Green LED indicating that the reject valve is in « production » position.
Protection of the electric motor if overload. General power off.
Protection salinometer card.
Feeding electric motor.
Stopping of the production and starting up of the rinsing semi-automatic temporized cycle.
32
36
33
37
34
FR/UK/ES Page 23/58