3.4 – STOPPING WITH WINTERING PROCEDURE (LONG TIME STOP)
1.
Use the AQUA-BASE wintering kit, which contains 1 cleaning solution + 1 preservation solution + filter 5µ.
2.
Rinse the membranes with fresh water as described in chapter (See 3.2p31).
Cleaning
3.
Fill the auxiliary tank with 10 liters of fresh water produced by the unit or dechlorinated mains water.
4.
Prepare the cleaning solution 752003-MC11 (see 752037-EXP10) by mixing it in the auxiliary tank (10 liters of water).
5.
Position the cleaning pipes (D) and (E) in the auxiliary tank and open the cleaning valve (11) to cleaning position.
6.
Turn the inlet valve (1) into the rinsing position.
7.
Open the air bleed valve (7) of the hydraulic amplifier (6).
8.
Disconnect the production valve (14) : for this, remove the screw of the little box (valve 14) and take off the connection, it's
necessary to isolate the principal main tank of fresh water.
9.
Press the green button « ON » (30) to start the pump and functonning in closed circuit.
10. Let the unit operate in this way in closed circuit for 15 minutes.
11. After this time, stop the unit (red button 31).
12. Empty the solution out of the auxiliary tank and clean it with fresh mains water.
13. Position the cleaning valve (11) in the reject position.
14. Rinse the membranes as described in chapter 3.2p31.
15. Fill the auxiliary tank with 10 liters of fresh water produced by the unit or dechlorinated mains water.
16. Prepare the cleaning solution 752003-MC3 (see 752037-EXP10) by mixing in the auxiliary tank (10 liters of water)..
17. Tilt the cleaning valve (11) to cleaning position.
18. Press the green button « ON » (30) to start the pump and functonning in closed circuit.
19. Let the unit operate in this way in closed circuit for 15 minutes.
20. After this time, stop the unit (red button).
21. Empty the solution out of the auxiliary tank and clean it with fresh mains water.
22. Position the cleaning valve (11) in the reject position.
23. Rinse the membranes as described in chapter 3.2p31.
Preservation
24. Fill the auxiliary tank with 10 litres of fresh water and add the AQUA-BASE preservation solution, Ref. 752039.
If the unit is to be stored at a temperature below 0°C, 20% of AQUA-BASE ANTI-FREEZE® ref.752004 must be added to the
preservation solution, during its preparation.
25. Make sure the cleaning valve (11) is in reject position.
26. Position the inlet valve (1) to take water from the auxiliary tank and direct it towards the LP pump.
27. Open the air bleed valve (7) of the hydraulic amplifier (6).
28. Disconnect the production valve (14) : for this, remove the screw of the little box (valve 14) and take off the connection, it's
necessary to isolate the principal main tank of fresh water.
29. Press the green button « ON » (30) to start the pump.
30. Stop the pump (red button) before the rinsing bucket is empty.
31. When pump is stopped,shut the hull valve (V0).
32. Whatever their condition, empty the filter (4) to avoid any bacteriological proliferation and if needs be, replace the filtration cartridge
of. (If you put the old cartridge back, wait until they are dry).
33. It is necessary that water remains in the membrane, make sure it cannot freeze (in the case of a possible risk, add to the storage
solution, the anti-freeze solution Ref. 752004 ( See chapter 3.3p31).
34. Not forget to re-connect the production valve (14).
If the unit is to be stored at a temperature below 0°C, 20% of AQUA-BASE ANTI-FREEZE® ref.752004 must be added
to the preservation solution, during its preparation.
NB : PRESERVATION OF THE PROCON PUMP : It is necessary to preserve the PROCON pump (with the glycerine), for it, refer to the
Technical Note NT0809 (ask this document to SLCE by email if it not supplies with the unit).
J:\Etude-3d\Aquaset\0-DOSSIER TECHNIQUES\1-sw-plaisance\ESW\00-ESW 0707\09- Manuels Utilisateur\DOC UTILISATEUR ESW FRUKES 2009-10-C.doc
FR/UK/ES Page 32/58
VERSION 2009-10-C