GB
TABLE OF INDICATIVE CALIBRATIONS
TABLE OF INDICATIVE CALIBRATIONS GAS XP60/2CE EVO G20 (NATURAL GAS)
Calibrations effected with pressure in chamber 0,1 mbar.
The definitive calibration must be done in operation by means of a combustion analiser.
THERMAL
POWER
ADJUSTMENT
1st
2nd
[NOTCH N°]
STAGE
STAGE
[kW]
[kW]
116
232
116
250
116
300
116
350
133
400
150
450
165
500
183
550
200
600
210
630
TABLE OF INDICATIVE CALIBRATIONS GAS XP60/2CE EVO G31 (L.P.G.)
Calibrations effected with pressure in chamber 0,1 mbar.
The definitive calibration must be done in operation by means of a combustion analiser.
THERMAL
POWER
ADJUSTMENT
1st
2nd
[NOTCH N°]
STAGE
STAGE
[kW]
[kW]
116
232
116
250
116
300
116
350
133
400
150
450
165
500
183
550
200
600
210
630
GAS XP60/2CE EVO
STARTING AND REGULATION
HEAD
FLOW
GAS HEAD
[Nm³/h]
PRESSURE
[mbar]
1
11.7
0.6
1.5
11.7
0.6
2
11.7
0.5
2.5
11.7
0.5
3
13.4
0.5
4
15.1
0.7
5
16.6
0.9
6
18.4
1.0
7
20.1
1.2
8
21.1
1.4
HEAD
FLOW
GAS HEAD
[Nm³/h]
PRESSURE
[mbar]
1.2
1
4.5
1.1
1.5
4.5
1.0
2
4.5
0.9
2.5
4.5
0.9
3
5.2
1.3
4
5.8
1.3
5
6.4
1.5
6
7.1
2.0
7
7.8
2.3
8
8.2
1st STAGE
AIR
PRESSURE OF
SHUTTE
VENTILATION
OPENING
AIR
[ ]
[mbar]
5°
1.2
5°
1.1
5°
1
5°
0.9
8°
0.9
10°
1.3
12°
1.4
14°
1.4
16°
1.5
18°
1.6
1st STAGE
AIR
PRESSURE OF
SHUTTE
VENTILATION
OPENING
AIR
[ ]
[mbar]
5°
1.2
1
5°
5°
0.9
5°
0.8
8°
0.9
10°
1.3
12°
1.2
14°
1.3
16°
1.4
18°
1.6
2nd STAGE
FLOW
HEAD
AIR
[Nm³/h]
PRESSURE
SHUTTE
[mbar]
OPENING
[ ]
23.3
1.6
22°
25.1
1.9
25°
30.1
2.9
30°
35.2
3.8
33°
40.2
4.6
36°
45.2
5.3
40°
50.2
7.3
48°
55.3
8.5
55°
60.3
9.8
65°
63.3
10.5
70°
2nd STAGE
FLOW
GAS HEAD
AIR
[Nm³/h]
PRESSURE
SHUTTE
[mbar]
OPENING
[ ]
4.9
9.0
22°
5.5
9.7
25°
7.1
11.7
30°
8.4
13.6
33°
10.2
15.6
36°
11.9
17.5
40°
14.0
19.5
48°
16.3
21.4
55°
18.1
23.3
65°
24.5
19.1
70°
071011_2_A
PRESSURE OF
VENTILATION
AIR
[mbar]
4.6
4.6
6.3
7.8
9.3
10.2
11.8
12.9
12.7
12.4
PRESSURE OF
VENTILATION
AIR
[mbar]
4.5
5.1
6.4
7.7
9.2
10.2
11.5
12.8
12.7
12.1
17