NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
H.) FUEL FILTER
CLEAN OR REPLACE TWICE A HEATING
SEASON OR AS NEED.
- Remove side cover screws using medium phillips
screwdriver.
- Disconnect switch wires from power switch and
remove side cover.
- Pull fuel line off fuel filter neck.
- Turn fuel filter 90˚ to counter clockwise and pull to
remove. (RMC-KFA45DGP-01/75TDGP-01 Model
only)
- Turn fuel filter 90˚ to clockwise and pull to remove
(RMC-KFA125TDGP-01/210TDGP-02 Models only).
- Wash fuel filter with clean fuel and replace in tank.
- Attach fuel line to fuel filter neck.
- Replace switch wires to power switch.
- Reinstall side cover.
I.) PUMP PRESSURE ADJUSTMENT
NOTE: Low BTU level pump pressure is increased
or decreased according to High BTU level
pump pressure, So, In case need Pump
pressure adjusting, Only adjust high BTU
level Pump Pressure.
- Turn BTU CONTROL Knob to HIGH BTU Level.
(See Operation, page 8, RMC-KFA210TDGP-02
Model only)
- Start heater (See Operation, page 8)
Allow motor to reach full speed
- Adjust pressure (Using a flat blade screwdriver) Turn
relief valve to clockwise to increase pressure.
Turn relief valve to counter clockwise to decrease
pressure.
- Set pump pressure to correct High BTU level pressure
for each model
- Stop heater (See Operation, page 8)
MODEL
RMC-KFA45DGP-01
RMC-KFA75TDGP-01
RMC-KFA125TDGP-01
RMC-KFA210TDGP-02
NOTE : USE ONLY ORIGINAL EQUIPMENT
REPLACEMENT PARTS.
Use of alternate or third party components will
void any warranty and may cause unsafe
operation condition.
Pump Pressure
High BTU level Low BTU level
2.8 psi
N/A
3.8 psi
N/A
5.5 psi
N/A
8.5 psi
6.5 psi
13
Fuel Filter
Screw
Side Cover
Power Switch
Figure 22. Fuel Filter Replacement
Flat blade
Screw driver
Pressure
Gauge
Pressure
Relief Valve
Gauge
RMC-45DGP-01
RMC-210TDGP-02 Model
RMC-75TDGP-01
RMC-125TDGP-01 Models
Figure 23. Adjusting Pump Pressure
Fuel line
Switch Wires
Relief Valve