NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
6. FUELING YOUR HEATER
NEVER FILL THE HEATER FUEL TANK IN THE LIVING SPACE : FILL THE TANK OUTDOORS.
DO NOT OVERFILL YOUR HEATER AND BE SURE HEATER IS LEVELED.
IMPORTANT NOTICE REGARDING FIRST IGNITION OF HEATER :
The first time you light the heater, it should be done outdoors. This allows the oils, etc. used in
manufacturing the heater to burn off outside.
WARNING!! : NEVER REFILL HEATER FUEL TANK WHEN HEATER IS OPERATING OR STILL HOT.
7. OPERATION
A.) VENTILATION
RISK OF INDOOR AIR POLLUTION/USE HEATER ONLY IN WELL VENTILATED AREAS.
Provide a fresh air opening of at least three square feet (2,800 sq. cm) for each 100,000 BTU/Hr.
rating. Provide extra fresh air if more heaters are being used.
Example :
B.) OPERATION
TO START HEATER
1. Fill fuel tank with kerosene or No. 1 fuel oil.
2. Attach fuel cap.
3. Plug power cord of heater into three-prong, grounded extension cord. Extension cord must be at
least six feet long. Extension Cord Wire Size Requirements
• 6 to 10 feet (1.8 to 3 meters) long, use 18 AWG conductor.
• 11 to 100 feet (3.4 to 30.5 meters) long, use 16 AWG conductor.
• 101 to 200 feet (30.8 to 61 meters) long, use 14 AWG conductor.
4. Turn "THERMOSTAT CONTROL Knob" to desired setting (Setting range : 40˚F ~ 110˚F)
(75/125TDGP-01/210TDGP-02 Models Only)
5. Turn "BTU control Knob" to desired level "High or LOW" (KFA210TDGP-02 Model only, See Figure 9.)
6. Push Power Switch to "ON" position, Power lndicator Lamp will light and heater will start.
NOTE : Room Temp. display indicates as following (RMC-KFA125TDGP-01/210TDGP-02 Models only)
when room temp. is less than 0
when room temp. is between 0
when room temp. is more than 99
If heater does not start, the thermostat setting may be too low, turn "thermostat Control Knob" to
higher position to start heater. If heater still does not start, turn power switch to "OFF" and then to
"ON" position. If heater still does not start, see Troubleshootiong Guide on page15.
NOTE : User can change BTU LEVEL "High or Low" while in operation by turnig BTU Control Knob.
If heater is operated by HIGH BTU LEVEL, Turn BTU Control Knob 90 to clockwise.
If heater is operated by LOW BTU LEVEL, Turn BTU Control Knob 90 to counter clockwise.
Lamp
Thermostat
LED Power
Control Knob
Switch
(75TDGP-01 Model Only)
RMC-KFA45DGP-01/75TDGP-01 Models
A RMC-KFA210TDGP-02 heater requires one of the following:
• a two-car garage door raised six inches (15.24 cm)
• a single-car garage door raised nine inches (22.86 cm)
• two, thirty-inch (76.20 cm) windows raised fifteen inches (38.1 cm)
; "L"
and 99
Room Temp. Display
Lamp
Thermostat
LED Power
Control Knob
Switch
RMC-KFA125TDGP-01/210TLDGP-02 Models
Figure 9. Controls for All Models
; Indicates in figure.
; "Hi"
BTU
Control Knob
Fan Guard
8
BTU Control Knob