Operating Conditions - Axis Q8665–LEPTZ Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 155
AXIS Q8665–LE PTZ Network Camera
Specifications

Operating Conditions

Product
AXIS Q8665–LE
De-icing
The product's automatic de-icing process starts when the product is switched on and the air
temperature is below 0 °C (32 °F). The de-icing process ensures that the product works properly
even at low temperatures. The de-icing period lasts for a maximum of 90 minutes. During this
period the camera is turned off.
Power
Power
Consumption
AXIS Q8665–LE
Unit
Base Unit
Light Sensor Box
Important
• To reduce the risk of fire, use UL-listed or CSA-certified telecommunication line cord.
• To maintain the IP rating of the light sensor box, the external diameter of the cables
must be 7 mm. The power supply cable between the pan/tilt unit and the light sensor
box cannot be longer than 10 m (33 ft.).
Classification
IEC/EN/UL 60529 IP66.
NEMA 250 Type 4X
IR active
Max: 113 W
Typical: 94 W
Input Voltage
24 V AC, 8 A
100 V AC, 200 W
120 V AC, 200 W
230 V AC, 200 W
Temperature
-40 °C to 55 °C
(-40 °F to 131 °F)
IR inactive
Max: 55 W
Typical: 40 W
18
Humidity
15 to 100% RH
(condensing)