Electrical; Plumbing - CMP DEL Ozone 25 Instrucciones De Instalación Y Manual Del Producto

Ocultar thumbs Ver también para DEL Ozone 25:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Section 2 Installation
2C. Electrical
2C-1. Main Power
This device is intended to be installed by a certified electrical
technician, in accordance with local electrical codes. Connect the DEL
Ozone generator to the pool timing clock so that the DEL Ozone
generator operates simultaneously with the pool pump. The DEL
Ozone generator has three available Knockouts for a 1/2 inch conduit
fitting, two on each side and one on the back. Remove only the ideal
Knockout and install the proper conduit fitting. Open the Enclosure
and locate the Terminal Block. Connect Line 1, Line 2, and Ground
to the Terminal Block as indicated by the label on the inside of the
enclosure door. Refer to the IMPORTANT SAFETY INSTRUCTIONS at
the beginning of this manual for important wiring information.
2C-2. Earth Grounding Lug
Using an 6 AWG (13.3 mm2) conductor, connect the Grounding lug
on the bottom of the DEL Ozone generator, marked to an appropriate
earth contact.
2D. Plumbing
Ozone gas is introduced to the pool circulation line using a venturi
injector. Suction developed by the venturi allows the DEL Ozone
generator to operate safely under vacuum.
Note: Water must not travel back to the ozone generator. Mounting
the unit above the water line and scheduled check valve replacement
will keep water from entering the DEL Ozone generator.
2D-1. Plumbing the Injector Manifold
The Injector Manifold must be installed in the pool's main return line
after all other pool equipment (pump, filter, heater, and cleaner).
Figure 2 shows the most basic installation. For installation with
additional oxidizers and pool cleaners, refer to Appendix A.
3

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Del ozone 50Del ozone 100

Tabla de contenido