INNOVATIVE ORBITAL SOLUTIONS
4.
HF antenna:
The HF antenna helps the electric arc ignition. If the HF antenna is not well installed, it is possible that
the power supply will not be able to create the electric arc. You have to put the spring on the ceramic
nozzle and to fix the lug on a part linked to the ground. Pay attention that the electric arc does not
ignite between the antenna and a part linked to the electrode.
5.
Connecting the weld head:
Ensure that the welding station is not activated before making these connections. SATO weld heads
are connected using a hose pack that includes:
A quick-release gas hose for connection at the front of the welding station.
Blue colour-coded (cold water) braided hose for the welding current with water coupling.
A red hose for hot water return.
A control cable for the feed motor.
A power cable for the feed motor.
An earthing cable.
Join
experience
0
SAS au capital de 135 720 € - RCS Romans B414 581 363 – Code APE 2841 Z – Siret 414 581 363 00028 – TVA FR13414 581 363
330B Route de Portes Les Valence - ZI Les Bosses - 26800 Etoile sur Rhône
Tél: +33 475 575 070 - Fax: +33 475 575 080 - commerce@axxair.com - www.axxair.com
- 19 -
ENGLISH