Control Board Installation
English
G-15 ELECTRONIC GATE SYSTEM CONTROL BOARD
INSTALLATION INSTRUCTIONS
IMPORTANT!
PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING
ANY CONNECTONS.
MAKE SURE 220VAC POWER SOURCE IS DISCONNECTED,
BREAKER IS OFF AND NO ONE IS GOING TO BE WORKING
ON THE POWER SUPPLY!
Electrical Connections:
The Hot Line from source attaches to the POWER L (21) tab on the board
The Neutral Line from source attaches to the POWER N (20) tab on the board
The EARTH PE (22) wire from source attaches top the chassis on the unit
The common wire from motor should be connected to the COM N (17) tab on the board
The clockwise rotation wire from motor should be connected to the MOTOR L1 (16) tab on the
board
The counter clockwise rotation wire from motor should be connected to the MOTOR L2 (15) tab
on the board
The lamp wire should be connected to the LAMP N and LP (18,19) tab on the board
Other Electrical Connections:
Connector (CON4) has been provided for connecting all the individual devices to the main
computer on the board all signal inputs are connected here to the main processing unit with a
signal wire and ground. More information will be provided later on.
Connector (CON4) has been made available for 18VDC auxiliary outputs. You may use these for
your other devices power needs, such as the sensors used in your particular installation.
Overload Detection:
The Control Board is equipped with an overload detection circuit, which will detect some
obstruction in the gates path.. The sensitivity is adjustable with the potentiometer labeled (RF2)
for open and labeled (RF1) for close.
The Overload must be adjusted to the most sensitive setting possible without causing self-tripping
due to the gates inherent friction. Try re-adjusting the potentiometer several times by small
increments testing the gate in both directions of travel until you are satisfied. Clockwise rotate
increase the force. Counter clockwise rotate decrease the force.
19