TERMINAL BLOCK CONNECTIONS

1
2
3
1-common
2-open/stop/close/stop cycle button
button 7,8-emergency stop 9-close limit 10-open limit 11-limit com 12,13-DC18V+ 14-DC18V-
INPUT
5-7 open limit (N.O.orN
6-7 close limit SW
3-4 (N.C.) photo beam
4-5(N.O.) open
1-2 (N.O.) alt OPN/CLS
1-7(N.O.) close
7-8(N.C.) emergency stop
15●
16●
15-motor counter clockwise rotation 16-motor clockwise rotation 17-motor common wire
18,19-lamp 20-220VAC neutral line 21-220VAC hot line 22-earth wire
4
5
6
7
FUNCTION
1-Stop when completely open
1-Stop when completely closed
1-Reverse if closing
2-Reset Timer (if used)
3-Disables closing
1-Open
2-Reverse if closing
3-Reset timer (if used)
1-Open
2-Close from full open
3-Stop from opening
1-Close
1-Stop when motor open and close
17●
18●
8
9
10
3-photo beam
4-common
TYPICAL DEVICES
Limit switch
Limit switch
Safe edge
Safety photo beam
Safety loop
Open push button
Card reader
Key pad
Radio control
Single push button
Single key switch
Close push button
Emergency stop push button
19●
20●
English
11
12
13
14
5-open button
21●
22●
6-close
21