PRASTEL EASYMINI Manual Del Usuario página 2

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
EASYMINI
1. GENERAL DESCRIPTION
EASYMINI is a slim-line proximity reader that operates a miniature solid-state relay upon recognition of a correctly enabled card or tag. The unit's relay output
can either by momentary (pulsed) or toggle (bi-stable).
The unit is designed for both internal and external use (IP 67). The resin filled interior makes it completely submersible in water and/or resistant to tamper. A
total of 200 different cards or tags can be programmed into the EASYMINI.
2. TECHNICAL CHARACTERISTICS - CONNECTIONS
Power supply
12 - 24 VDC
Consumption
40 mA
Reading technology
proximity, 125 kHz
Range
9 cm with BDGPROX card, 4 cm with TAGPROX tag
Memory capacity
200 users
No. of output relays
1 – pulsed (1 sec) or bi-stable. Selectable
Relay contact rating
1 A @ 30 VDC
Safety devices
Interior completely filled with resin, magnetic tamper
Indicators
two-colour LED (Red/Green), buzzer
Protection class
I.P. 67
Dimensions/weight
28 x 92 x 12, 165 g
3. OPERATION
The programming operations that can be performed on EASYMINI are:
programming a single badge
-
-
disabling a single badge
-
disabling all badges
The built-in two-colour red/green LED and the buzzer provide all the indications necessary to identify the current programming phase
and relay status.
Programming a single badge
If no badges are present in memory:
1.
Hold a badge in front of the EASYMINI for at least 6 seconds and remove it as soon as the led turns to green.
2.
Present the badges to be entered in front of the EASYMINI. At each entry, the green LED flashes.
3.
Wait 10 seconds until the LED becomes red again.
If badges are already present in memory:
1.
Hold an already programmed badge in front of the EASYMINI for at least 6 seconds and remove it as soon as the led turns to green.
2.
Present the badges to be entered in front of the EASYMINI. At each entry, the green LED flashes.
3.
Wait 10 seconds until the LED becomes steady red again.
Disabling a single badge
1.
Hold an already programmed badge in front of the EASYMINI for at least 10 seconds and remove it as soon as the led starts flashing red.
2.
Present the badges to be disabled in front of the EASYMINI. At each entry, the LED flashes red at a higher frequency.
3.
Wait 10 seconds until the LED becomes steady red again.
Disabling all badges
Take extreme care when carrying out the following operation. It will cancel all data from the memory.
Once the cancellation procedure has been carried out, the programming cannot be recovered.
For better security, only the badge which was first programmed in the EASYMINI is able to perform this operation
WARNING: if the first badge is misplaced, it will no longer be possible to totally delete the memory.
1.
Hold the badge which was first programmed in front of the EASYMINI for at least 10 seconds and remove it as soon as the led starts flashing red.
2.
Present the same badge for at least 3 seconds and remove it as soon as the led starts flashing at a higher frequency.
3.
MEMORY IS NOW ERASED and the LED becomes steady red again.
4. LED DRIVING
If the ORANGE and CYAN wires are left unconnected or tied to 5VDC the status of the led is driven by the reader itself.
If one or both of the ORANGE and CYAN wires are connected to GROUND, the status of the LED changes as follows:
ORANGE wire
CYAN wire
GROUND
GROUND
GROUND
5VDC or floating
5VDC or floating
GROUND
5. RELAY OPERATING MODE
If the YELLOW wire is left unconnected or tied to 5VDC, the contact type is N.O.
If the YELLOW wire is tied to GROUND, the contact type is N.C.
If the BROWN wire is left unconnected or tied to 5VDC the relay mode is pulsed (1 second)
If the BROWN wire is tied to GROUND, the relay mode is toggle/bi-stable.
6. TAMPER SWITCH
EASYMINI is equipped with an internal REED switch, which is activated by the magnet given as issued . The switch may be used as anti-tampering.
DECLARATION OF CONFORMITY
Prastel declares that the following equipment PROXIMITY READER EASYMINI IS IN ACCORDANCE with the 99/05/EC (R&TTE) directive.
The complete declaration of conformity is available in Prastel.
ENGLISH
Colour
Red
Black
Green
White
Yellow
Brown
Orange
Cyan
Rose
Violet
LED status
OFF
RED
GREEN
Function
12 – 24 VDC
GROUND
Relay contact
Relay contact
Relay contact type
Relay mode
Red LED driving
Green LED driving
TAMPER
TAMPER
0523
ISEASYMEU_06_14

Publicidad

Tabla de contenido
loading

Tabla de contenido