Mitsubishi Electric EHPT Serie Manual De Instalación página 23

Tabla de contenido

Publicidad

5
System Set Up
<Main Controller Menu Tree>
Initial
Main screen
* Short press for 1 Zone system.
*
Information
F1
Option
F4
F1
F2
F3
F4
Menu
Main
menu
Menu
Main
menu
Hot Water (DHW)
Heating/Cooling
Schedule timer
Holiday
mode
Initial
settings
<Continued to next page.>
Forced DHW
DHW
Heating/Cooling
Energy monitor
F1
DHW
F3
Legionella
F2
(
DHW
F4
(
Legionella
F1
(Zone1)
F2
(Zone2)
F3
(PREVIEW)
(
EDIT)
F4
Schedule2 period setting screen1
F4
(
EDIT)
Schedule2 period
preview screen
Schedule1/2 select
DHW
Heating/
Cooling
F3
Holiday mode setting
( EDIT)
Date/Time
Language
Summer time
Temp. display
Contact number
Time display
°C/°F
Room sensor settings
ON ( )/OFF
ON ( )/Prohibited ( )/Timer ( )
ON ( )/Prohibited ( )/Timer ( )
Consumed electrical energy
Delivered energy
Normal/Eco
Active/Non active
DHW max. temp.
EDIT)
DHW max. temp. drop
DHW max. operation time
DHW mode restriction
DHW recharge
Hot water temp.
Frequency
EDIT)
Start time
Max. operation time
Duration of max. temp.
Heating room temp.(
) / Heating flow temp.(
Heating room temp.(
) / Heating flow temp.(
Compensation curve preview
F1
Zone1/2 select
Compensation curve edit
F2
F1
Zone1/2 select
Heating
F1
Zone1/2 select
Schedule1
Cooling
DHW
F1
Zone1/2 select
Heating
F1
Zone1/2 select
Schedule2
Cooling
DHW
Active/Non active
Active/Non active
Zone1
F1
F2
Zone1/2 select
Zone2
yyyy/mm/dd/hh:mm
EN/FR/DE/SV/ES/IT/DA/NL/FI/NO/PT/BG/PL/CZ/RU/TR/SL
OFF/ON
OFF/Room/Tank/Room&Tank
hh:mm/hh:mm AM/AM hh:mm
°C/°F
Zone1
Room RC zone select
F1
F2
Zone1/2 select
Sensor setting
Zone2
) / Heating compensation curve(
) / Heating compensation curve(
Curve parameters
F2
F3
Zone1
Adjustment
F4
Curve parameters
F2
F3
Zone2
Adjustment
F4
Term setting
F3
F4
Schedule timer preview
F4
Day
Zone1
select
Schedule timer preview
F4
Day
Zone2
select
Schedule timer preview
F4
Day
Zone1
select
Schedule timer preview
F4
Day
Zone2
select
Schedule timer preview
F4
Day
select
Schedule timer preview
F4
Day
Zone1
select
Schedule timer preview
F4
Day
Zone2
select
Schedule timer preview
F4
Day
Zone1
select
Schedule timer preview
F4
Day
Zone2
select
Schedule timer preview
F4
Day
select
Heating room temp.
Heating flow temp.
Cooling flow temp.
Heating room temp.
Heating flow temp.
Cooling flow temp.
Sensor setting
TH1/Main RC/
Room RC1-8/ "Time/
Zone"
Time setting
Select Time/Zone
Sensor setting
Sensor setting
TH1/Main RC/
Room RC1-8/ "Time/
Zone"
Time setting
Select Time/Zone
Sensor setting
Unrestricted access
Installer only
Long press
en
) / Cooling flow temp.
) / Cooling flow temp.
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
Temp.setting
save
Time select
save
22

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido