PRODUCT OVERVIEW
PRODUCT OVERVIEW
PRODUCT OVERVIEW
PRODUCT OVERVIEW
The MLX24V rail mount, vehicle loop detector is compatible with most gate operators. The MLX24V may be
used in Center, Safety and Exit loop positions. The display feature makes set-up easy by displaying the
optimum sensitivity setting required to detect a vehicle positioned on the loop. Ten sensitivity settings allow
for fine adjustment of detection level.
The MLX24V provides relay contact outputs indicating vehicle presence. The MLX24V features automatic
sensitivity boost (ASB), delay, fail-safe/fail-secure and infinite or normal (5 min.) presence. Four frequency
settings provide flexibility in preventing crosstalk in multi-loop applications.
Sensitivity
Display
Loop frequency
Loop inductance
Grounded loop
Automatic tuning
Environmental tracking
Surge protection
Presence relay
Contact ratings
Power / loop fault indicator
Detect / frequency count indicator
ASB (Automatic Sensitivity Boost)
Power
Operating Current (Standby/detect)
Operating temperature
Dimensions (L x W x H)
Mounting method
Weight
Connector
MLX24V
09/12/2013
ENGLISH
Specifications
Specifications
Specifications
Specifications
10 levels, 0-9
Indicates optimum sensitivity level, 0-9
Diagnostic aid
4 settings (low, med-low, med-hi, high)
20...2000µH (Q factor > 5)
Isolation transformer allows operation with poor quality
loops
Detector tunes to loop on power-up and following
frequency count function
Automatic compensation
Loop circuitry protected by surge suppressors
SPDT relay contacts (form C)
1A @ 24VDC...120VAC
Green LED
Red LED
Increases sensitivity after initial detection to prevent
dropout due to high-bed vehicles
12VDC...24VDC, 24VAC (see Cautions and Warnings)
15mA/45mA
-40˚C...82˚C (-40˚F...180˚F)
0...95% relative humidity
2.9"(74mm) x 0.9"(23mm) x 3.3"(84mm)
DIN rail mount - 35mm
0.25 lbs. (113 g)
8 screw terminals
14