Double-feed sensor settings
The scanner contains a sensor that checks the thickness of all documents
to avoid feeding more than one document at a time. If a double feed
occurs, the scanner sends a message to the host computer and the
ERROR LED flashes.
If the whole document is thicker than standard paper grammage, then the
double-feed control must be disabled. The control (Double Feed Enable)
can be found in the Scanner settings dialogue.
If the documents to be scanned are thick, and the double-feed alarm
occurs frequently, even when scanning single documents, you can modify
the sensitivity of the Thickness photosensor by adjusting the Document
feed detection "Threshold" control in the Scanner settings dialogue. The
standard adjustment value is around 150. If the alarm occurs for each
document capture, then the adjustment value must be increased. On the
contrary, if two documents are fed at the same time but the alarm is not
activated, then the adjustment value must be decreased.

Control Panel

When you switch the unit ON, a self-test checks that the scanner is
functioning correctly.
After
the
configuration
procedure is completed,
the scanner is ready for
use and on the Control
Panel the following status
information is provided.
Ref.
Description
1
Activates the transport motor to eject any jammed document or paper fragment.
2
ON
Flashing
3
ON
OFF
4
ON
Flashing slowly
5
Reset the error condition due to a unsuccessful insertion operation
OLISCAN A600 - USER'S GUIDE
1
2
EJECT KEY
ERROR LED (ORANGE)
Functionality or connection error , scanner offline
When feeder LED flashes it signals a double-feed alarm
FEEDER LED (GREEN)
Document present in the feeder
No documents in the feeder
ONLINE LED (BLUE)
Scanner online
Scanner is in standby mode
RESET KEY
5
3
4
15