5. Technical data
Supply voltage:
DC power supply:
Display:
Data retention:
Polarity of the inputs:
Input resistance:
DC power supply:
Input level:
typ. low level:
typ. high level:
Fmax:*
Count frequency:
Minimum pulse length for the reset input:
Input sensitivity:
Standard sensitivity:
DC power supply:
Pulse shape:
Ambient temperature:
-20 ... +65°C at 10 ... 26 V DC
-20 ... +55°C at >26 ... 30 V DC
Storage temperature:
-25 to +70°C [-9 to 158°F]
EMC:
In compliance with the EC Directive
2004/108/EEC
Noise emission:
Noise immunity:
* at maximum frequency (50-50 duty cycle)
MN05401014E
10 – 30V DC/max. 40 mA
6 digits, red 7 segment
LED display, height 8 mm
[0.31 in.]
EEPROM
Programmable, npn or pnp
(sinking or sourcing) for all
inputs
appr. 5 kOhm
24V
12V
Standard
2.5V
2.0V
22.0V
10V
60 kHz
20 kHz
5 ms
Low: 0 – 0.2 x U B [V DC]
High: 0.6 x U B – 30 [V DC]
U B = Supply Voltage
any*,
Schmitt Trigger inputs
EN 61 000-6-3/
EN 55 011 Class B
EN 61 000-6-2
Housing:
Weight:
Front panel rating: IP 65
Cleaning:
The front of the units is to be cleaned only with a
soft cloth moistened with water.
6. Terminal assignment
1 10 – 30V DC
2 0V GND
3 INP
4 –
5 Reset
For front panel mounting
48 x 24 mm
[1.89 x 0.94 in.]
acc. to DIN 43700,
RAL 7021, dark grey
appr. 50 g [1.76 oz.]
3