5. Technical data

Supply voltage
Power supply:
Display:
Data retention:
Polarity of the inputs:
Input resistance:
Count frequency:
DC power supply:
Input level:
typ. low level:
typ. high level:
Fmax:
tot.tac
tot.tot
tot.ti
1)
tot.ti
2)
1) Start Gate.Lo Inp B not active
2) Start InpB.InpB and Inp B connected with Inp A
* at maximum frequency square wave pulses 1:1
MN05401010E
The programming routine
is repeated once more.
The values set until now
can be checked and
modified.
The programming routine
wil be exited and all
values set will be stored
as new parameters.
Afterwards the device is
ready for operation.
10 – 30V DC/max. 40 mA
with inverse-polarity protection
6 digits, red 7 segment
LED display, height 8 mm
[0.31 in.]
EEPROM
Programmable, npn or pnp
(sinking or sourcing) for all
inputs
appr. 5 kΩ
24V
12V
10 – 30V
Standard
5V
2.5V
2.0V 1.0V
22.0V 10V
4.0V
kHz
kHz
kHz
35
20
8
60
20
8
40
20
8
15
10
8
Frequency measurement:
Error:
Measuring principle:
< 38 Hz:
> 38 Hz:
Time ranges:
Seconds
Minutes
Hours
h.min.s
Error
Minimum pulse length for the Reset input:
Input sensitivity:
Standard sensitivity:
5V sensitivity:
Pulse shape:
Ambient temperature:
–20 ... +65°C at 10 ... 26 V DC
–20 ... +55°C at >26 ... 30 V DC
Storage temperature:
–25 to +70°C [-9 to 158°F]
EMC:
In compliance with the EC Directive
Noise emission
Noise immunity
Housing:
For front panel mounting: 48 x 24 mm
[3.78 x 1.89 in.] acc. to DIN 43700, RAL7021,
dark grey
Weight:
Front panel rating: IP 65
Cleaning:
The front of the unit is to be cleaned only with a
soft cloth moistened with water.
< 0.1 %
period measurement
gating time measurement
gating time = 26.3 ms
0.001 s – 999 999 s
0.001min – 999 999 min
0.001 h – 999 999 h
00 h 00 min 01 s
– 99 h 59 min 59 s
<50 ppm
5 ms
Low: 0 – 0.2 x U B [V DC]
High: 0.6 x U B – 30 [V DC]
U B = Supply Voltage
Low: 0 – 2V DC
High: 4 – 30V DC
any,
Schmitt-Trigger inputs
2004/108/EEC
EN 61 000-6-3/
EN 55 011 Class B
EN 61 000-6-2
appr. 50 g [5.29 oz.]