INTRODUCTION

Pump Works submersible sump pumps are recommended for use in basins or lift stations and are
suitable for pumping clear water . Do not use the pumps in applications where effluent (grey water),
sewage or any other debris (gravel, sand, floating debris, etc . ) is present .
This owner's manual provides you with the information required to safely own and operate your
Pump Works submersible sump pump . Retain these instructions for future reference . The submersible
sump pump you have purchased is of the highest quality workmanship and material, and has been
engineered to provide long and reliable service . This product has been carefully tested, inspected, and
packaged to ensure safe delivery and operation . Please examine your product carefully to ensure that
no damage occurred during shipment . If damage has occurred, please contact the place of purchase .
They will assist you in replacement or repair, if required .
WARNING: READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE,
OR SERVICE YOUR PUMP WORKS PRODUCT. KNOW THE PRODUCT'S APPLICATION, LIMITATIONS, AND
POTENTIAL HAZARDS. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
W A R N I N G

SPECIFICATIONS

Discharge Size:
1-1/2" FNPT
Intake Size:
1/8" screened opening
Pump Housing:
Thermoplastic
Volute:
Thermoplastic
Screen:
Thermoplastic
Impeller:
Vortex design
Motor:
Single-phase PSC with automatic reset thermal overload
protection
Hardware:
Stainless steel
Bearings:
Ball bearings
Pump Shaft Seal:
Double lip seal
Power Cord:
18 AWG 3-conductor
This unit is permanently lubricated . Oiling is not required . Do not, in any case, open the sealed portion
of the unit or remove housing screws .

INSTALLATION

The pump must be installed in a suitable gas-tight basin that is at least 14" in diameter and 18" deep .
Clean any debris from sump pit and set pump in center of pit . A solid bottom will prevent clogging of
the pump from sand and dirt .
The pump must be placed on a hard level surface . Never place the pump directly on clay, earth, or
gravel surfaces . These surfaces contain small stones, gravel, sand etc . that may clog or damage the
pump and cause pump failure .
Connect discharge piping . Use pipe joint compound at all connections . Sump pumps can be piped to
discharge into the house drainage system, to a dry well, splash block, or to a storm drain depending on
local plumbing codes . The discharge pipe should be as short as possible and contain as few elbows as
necessary . The discharge pipe should be the same diameter as the discharge size to reduce pipe friction
losses . Smaller pipe will restrict capacity and reduce pump performance . The sump pump comes with
a 1-1/2" female pipe thread discharge .
Support pump and piping while assembling and when installed . Failure to do so may cause piping to
break, pump failure, motor bearing failures, etc .
Always install a union in the discharge line just above the sump pit to allow for easy removal of the
pump for cleaning or repair .
A check valve must be used in the discharge line to prevent back flow of liquid into the basin .
When a check valve is used, drill a relief hole (3/16" diameter) in the discharge pipe . This hole should be
located below the floor line between the pump discharge and the check valve . Unless such a relief hole
is provided, the pump could "air lock" and will not pump water even though it will run .
Be sure that the float has adequate clearance and cannot become stuck on the sides of the sump . Do
not allow the cord to interfere with the free movement of the float or to drape over the motor housing .
The cord should be taped to the pump discharge piping with electrical tape .
D A N G E R
Test operation of the sump system following the instructions outlined in the Sump System Operation
Testing section of this manual . Do not attempt to operate the pump without water; this will damage
the seals and bearings and could result in permanent damage to the pump .
Place cover over sump . The cover will help prevent solid debris from filling the pit and will guard
against accidental injury .
WARNING: Always disconnect the electrical power before touching the pump or discharge when
water is present in the sump . Failure to do so can result in hazardous electrical shock .

ELECTRICAL CONNECTIONS

Check local electrical and building codes before installation . The installation must be in accordance with
their regulations as well as the most recent National Electrical Code (NEC) .
To conform to the National Electrical Code, all pumps must be wired with 14 AWG or larger wire . For
runs up to 250', 14 AWG wire is sufficient . For longer runs, consult a qualified electrician or the factory .
Check the pump label for proper voltage required . Do not connect to voltage other than that shown .
A ground fault circuit interrupter (GFCI) is required .
The pump should be connected or wired to its own circuit with no other outlets or equipment in the circuit
line . The fuses and circuit breaker should be of ample capacity in the electrical circuit . See table below .
PUMP
HP
VOLTAGE
PW-SP25T
1/4
PW-SP33T
1/3
PW-SP50T
1/2

SUMP SYSTEM OPERATION TESTING

TESTING PUMP OPERATION
1 . These pumps are equipped with a float switch . Be sure that the float has adequate clearance
and cannot become stuck on the sides of the sump .
2 . When the pumps are installed in a basin with a sealed cover, switch operation cannot be
observed . The sump cover will typically have a spare hole that is plugged with a rubber plug .
This plug can be removed to observe switch operation .
3 . Plug the power cord into a grounded receptacle with a voltage consistent with the pump
voltage as indicated on the pump nameplate .
4 . Be sure the gate valve in the discharge line is open .
5 . Run water into the sump basin until the primary pump is activated .
a . Do not attempt to run the pump without water; this could result in permanent damage
to the pump .
6 . Confirm that the primary pump and its control switch are functioning as intended .
7 . Confirm that ON-OFF levels are within specification and that no potential obstructions exist that
could inhibit switch operation .
8 . Confirm that there are no leaks in the primary pump discharge plumbing and main home drain
pipe plumbing .
a . It is normal for a stream of water to spray from the air bleed hole in the plumbing of
the primary pump . Confirm that this spray is captured within the sump basin .
9 . Allow the pump to operate through several on-off cycles .
If the pump does not operate properly, consult the troubleshooting chart in this manual . If trouble
cannot be located with the steps shown, consult your pump dealer or call 1-888-956-0000 .
Do not let the unit run dry (without liquid) . It is designed to be cooled by pumping fluid . Damage to
the seal and motor may occur if the pump is allowed to run dry .
If the unit is going to be idle for a period of time, follow the cleaning instructions outlined in the next
section . Do not let the unit freeze in the wintertime . This may cause cracking or distortion that may
destroy the unit .
WARNING
BREAKER AMPS
115
15
115
15
115
15
3