d. Hold the left key pressed and press the right
key to switch to the first parameter.
e. After releasing the keys, the display alter-
nates between the menu title and the current
menu item setting. After pressing any key,
only the menu item setting is displayed.
f. Press the right key to switch the menu item
setting to the next value. If figures are to be
input (e.g. when setting the scaling factor),
first select the decade using the left key, and
then set the value using the right key.
g. Hold the left key pressed and press the right
key to switch to the next menu item.
h. The last menu title "EndPro" allows the user,
when selecting "Yes", to exit the programming
menu and to store the new values. If "no" is
selected, the programming routine is repeat-
ed, and the latest values set remain active.
They can now be checked again or modified.
3. Programming routine
The first menu item is the selection of the basic
operating mode, which determines the functions
of the device.
2
Operating mode pulse
counter.
Operating mode frequency
meter.
Operating mode time meter.
Pulse counter/Po si ti on indicator
mode
1. Description
• 6-digit display counter with SET/RESET-
function
• Red LED display, character height 8 mm
[0.31 in.]
• Display range from -199 999 to 999 999
• Lead zero blanking
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Counter operating modes:
Count input INP A + count direction input
INP B (Cnt.Dir)
Differential count INP A – INP B (up.dn)
Totalizing INP A + INP B (up.up)
Count Up/Down INP A 90° INP B x 1 (quAd)
Count Up/Down INP A 90° INP B x 2 (quAd 2)
Count Up/Down INP A 90° INP B x 4 (quAd 4)
• Optional optocoupler output
2. Inputs
INP A
Dynamic count input.
INP B
Dynamic count input.
SET/RESET
Dynamic SET/RESET input. Linked in parallel to
the red SET/RESET key. Resets the counter to
the predefined setting value.
3. Programming routine
The programmable parameters of the device are
described below in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factory
settings.
MN05401011E