3.8 SET value
For programming the decimal point see 4.6.
3.9 End of programming
4
The device will be set to
the set point by pressing
the red SET/RESET key
or activating the
SET/RESET input.
SET value -199999 –
999999 (number of
decimal places depends
on the decimal point
option)
The programming routine
is repeated once more.
The values set until now
can be checked and
modified.
The programming routine
will be exited and all
values set will be stored
as new parameters.
Afterwards the device is
ready for operation.
Tachometer/Frequency/Rate meter
mode
1. Description
• 6 digit frequency meter
• Red LED display, character height 8 mm
[0.31 in.]
• Display range from 0 to 999 999
• Lead zero blanking
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Value conversion and display in 1/s or 1/min
• Optional optocoupler output
2. Inputs
INP A
Dynamic count input.
3. Programming routine
The programmable parameters of the device are
described below in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factory
settings.
3.1 Polarity of the inputs
npn: sinking sensor
pnp: sourcing sensor
MN05401011E