Oki BVX-200 Guia Del Usuario página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5.4 Filter Replacement Procedure:
1. Turn unit off.
2. Disconnect the power cord.
3. Unlatch the filter cover (see illustration on right).
4. Remove filter cover.
5. Replace the filters. (Pre-filter/main filter). Ensure to place main filter inside
the alignment pins so that interlock switch is depressed.
6. Replace filter cover and ensure proper fit on bottom housing. Hook both
latches into filter cover and press down carefully.
Caution!
Do not use force. If latches do not close, check proper
seating of filter cover on bottom housing.
7. Reconnect power cord and turn system on.
8. If unit does not operate, refer to troubleshooting section.
Notice:
Always use new replacement filters!
Place Filter inside
the Alignment Pins
OK International ¥ Copyright © All Rights Reserved ¥ BVX-200 Rev 01-15-04
Step 2:
Unhook
Latch
Step 1:
Pull & Lift
Latch
11
Filter
On/Off
Switch
Latch

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido