APPENDIX A: APPLICATION NOTE

Quick guide to certificate a telecommunication installation.
A.- Capturing reference measures.
1.-
Connect a pigtail to the PROLITE-105 output connector.
2.-
Connect another pigtail to the OLT input connector of the PROLITE-67 (See
figure A).
3.-
Use the SC-SC adapter to connect both pigtails.
4.-
Power on the PROLITE-105 and the PROLITE-67.
5.-
Select the ATTENUATION TEST function in the PROLITE-67.
6.-
Press once the SEQ
PROLITE-105.
7.-
Capture the reference values of the wavelengths by pressing
simultaneously for 1 second both cursor keys in the PROLITE-67.
8.-
Now you can measure at each access point its attenuation.
07-2012
key to select the SIMULTANEOUS mode in the