Promax PROLITE-67 Manual De Instrucciones página 84

Medidor selectivo de potencia óptica y comprobador ftth
Ocultar thumbs Ver también para PROLITE-67:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

To access this function:
1.-
Press MENU
2.-
Press
3.-
Press SEL
Next it is described each of the fields on the screen:
Upstream signal (1310 nm / 1610 nm)
[1]
Upstream Wavelength signal. Selectable by the user. For GPON networks is
1310 nm. For RFoG networks is 1610 nm.
[2]
Absolute optical power of the signal at the corresponding wavelenght.
Absolute measurement mode is the absolute power of signal in dBm (dB
referred to 1mW).
[3]
Graphical representation of the Upstream power. Arrows indicate the upper
and lower threshold values corresponding to the threshold group selected.
The solid bar indicates the average power. The dashed bar indicates the the
peak value on bursts.
[4]
Threshold selected group (code and name identification). The sign next to the
threshold group indicates if the power value is within ( ), higher ( ) or lower
( ) respect to the threshold group.
Page 22
[2].
or
[5] until pointing at xPON POWER METER.
[4] to get into this function (see figure below).
Figure 10.- xPON POWER METER screen.
USER'S MANUAL. PROLITE-67
07-2012

Publicidad

Tabla de contenido
loading

Tabla de contenido