25 / EN
•
Generally, for different wall types, especially walls with bricks, perforated blocks,
or blocks with limited firmness, this mounting must be checked for safety. The wall
mounting screws must be able to support three times the weight of the heater
full of water.
•
Do not place objects under the water heater, to avoid damages.
Before connecting the heater, you must:
•
Check that the product characteristics comply with the requirements for its correct
operation. See the Electrical Specifications Table.
ELECTRICAL SPECIFICATIONS TABLE
Tipo
Power (W)
Supply voltage (VAC)
Phase
Amperage (A)
Recommended breaker (A)
Required cable diameter
*For commercial use, we recommend 3 phases
Cable most be 100% copper.
This heater must be installed according to the following indications regarding the
presence of:
•
Humidity: do not install the appliance in humid environments.
•
Ice: do not install the appliance in environments with a probability of temperatures
dropping to critical levels with a risk of ice formation.
•
Sun rays: do not expose the appliance directly to solar rays, not even through
glass.
•
Dust/vapors/gases: do not install the appliance in notably aggressive
environments, such as those with acid vapors, dusts, or saturated gas.
•
Electric shock: do not install the appliance directly on electrical lines that are not
protected from voltage fluctuations.
Modelo
Eleva 15 kW
Electric Instantaneous Water Heater
15000
220
2*
68
3 x 30 A (Double pole)
3 x 10 AWG