General Introduction; Description Of Terminals; Technical Characteristics - Comelit SimpleKey SK9000I Manual Tecnico

Módulo de control de accesos
Tabla de contenido

Publicidad

General introduction

The SK9000 unit is a stand-alone control unit with an integral reader
which is used to manage the electronic keys SK9050 and SK9052. It
is used to control access to a door fitted with an electronic lock or an
automatic device.
It is supplied ready for use. It is initialised by swiping the first token
over the unused unit which then becomes the master fob to which you
can then add other tokens.
Layout of the unit
The card is made up of:
- a switch used to access the programming
- three push buttons that are used to affect the parameters
- the three LED's that show the statuses of the unit
- connection terminals
- a J5 firmware update connector

Description of terminals

AL: Power supply 12 - 33 V dc or 12 - 24 V ac
J1:communication bus SK9093
J2: NO/NC relay output
J3: exit push button
J4: integral reader
Programming modes
The S3 switch is used to switch between programming modes.
S3 in "0" position ⇒ Operating mode
S3 in "ON" position ⇒ Programming mode
Note: In programming mode the L2 LED and the reader LED flash
rapidly.
You must go back to operating mode for the unit to manage access.
Setting the opening timer
- Turn switch S3 to "ON" (Programming)
- Press button S1 several times to adjust the time units (one press
per second). Once S3 has switched back to operating mode a double
confirmation beep will validate this for you.
The minimum timing setting is 1 second.
The maximum timing setting is 99 seconds.
The unit is supplied with a 5 second opening time set by the
factory.
User's token management
1. Master fob.
The first token swiped in the unit will become the master fob. The
green LED will flash three times to indicate master fob creation. It
will enable you to enter programming mode without having to access
the unit.
4
2. Adding a user token
The unit must be in OPERATING mode (switch S3 in position "0").
Pass the token in front of the reader. The LED will flash quickly (green/
red) and you are in programming mode. To add user tokens you just
have to pass them in front of the reader to register them.
To exit programming mode, pass the master fob again or wait 15
seconds without doing anything. (The flashing will stop)
3. Partial reset - reset of Master Fob
In case the Master Fob is lost, it is possible to only reset the Master
Fob in order to program another token as Master Fob
- Turn Switch S3 to "ON" (Programming)
- Press S2 for 5 seconds, till L3 LED lights on
- Release S2
- Switch back to Operating Mode (a double beep tells you that the unit
has been partially reset)
In this moment, the first token you swipe to the reader WILL BECOME
THE NEW Master Fob
4. Complete reset
- Turn switch S3 to "ON" (Programming)
- Press S2 for 10 seconds. After 5 seconds L3 lights on (Partial
Reset). Keep pressed 5 seconds again till L2 LED flashes quicky
(Complete Reset)
- Release S2
- Switch back to Operating Mode (a double beep tells you that the unit
has been completely reset)
Resetting to zero enables the initialisation process:
- the password to access the unit is "0000".
- user tokens and the master fob are deleted.
5. Deleting a token using the SK9093 kit
Using the SK9093 software, supplied separately, it is possible to
display the tokens programmed into the unit and delete them. To do
this you just have to connect to the unit using the cable supplied with
the kit and launch the program.
- Click on "Token management" then "Scan the list of tokens" to
display them.
- You can then either delete the user tokens: check the tokens then
click on "delete the selected token(s)" or delete the whole memory:
Click on "Delete all tokens", the unit will then be completely cleared
and the first token swiped over the reader will become your master
fob.
Normal working of the unit
When the module is in normal Operating Mode, inside the red Led L1
is fixed, and the red L2 flashes slowly. Outside, the reader is fixed red,
switching off briefly every 3 seconds.
If the unit is not working properly, these LEDs are giving different
indications. In this case turn the power OFF and then ON again. If
this does not work, please contact our after sales service department.

Technical characteristics

• Opening time can be adjusted from between 1 and 99 seconds.
• Output via dry contact max. 5A at 250 VAC
• Power consumption: 70 mA when idle, 160 mA when relay active
• Operating temperature: -30°C - +55°C
• Operating voltage: 12 - 33 V dc or 12 - 24 V ac
• Dimensions (H X L X D): 62 x 88 x 23 mmz

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Simple key ft sk9000

Tabla de contenido