INSTALLATION
Installing the Control Box
Use the following procedure to install the control box.
WARNING
Control box must be mounted in a vertical surface.
Mounting control box in a horizontal surface may result in
the collection of liquids and lead to electric shock.
NOTICE
Install remote-mounted control box outside of areas subject
to temperatures above 104°F (40°C). Excessive temperatures
will cause controls to overheat, malfunction, and fail.
IMPORTANT NOTE:
Remote-mounted control boxes and control switches must be
installed in a cool, dry location as far away from any heat zone
as possible. Do not mount control boxes directly on, under, or
above unit. Do not mount control boxes in direct contact with
any heated surface or near any steam generating equipment.
1. Cut and drill the appropriate holes in the vertical surface
where the control box will be installed. Refer to the "Control
Box Cutout and Screw Hole Dimensions" illustration for
cutout and screw hole dimensions.
NOTE: Make sure the control box installation location provides
enough space behind the vertical surface for the depth
of the control box and electrical connections.
2. Complete the routing of the element wire leads and the
LED wire leads from the unit to meet up with the control
box through the cutout.
3. Have a qualified electrician make the appropriate electrical
connections from the unit to the control box. Refer to the
wiring diagram included with the unit.
50 mm
(2")
172 mm (10-7/16")
Control Box Cutout and Screw Hole Dimensions
GM5AHL Control Box Electrical Connections
4. Position the control box into the cutout opening through the
front side. Make sure that none of the electrical wires are
pinched or stressed.
5. Apply a 6 mm (1/4") bead of NSF-approved silicone sealant
where the control box flange will contact the cabinet surface.
6. Fasten the control box to the vertical surface using four
screws (not supplied).
Control Box
162 mm
(6-3/8")
51 mm
(2")
8
Power
Power
Cord
to Unit
Heat
Screw
Installing the Control Box
1.5 mm
(1/16")
Form No. GM5AHCEM-0619
Access
Cover
Control
Box
Cutout