DIVACONDENS D PLUS F 24
Con-
Description
tents
DHW user max. setpoint (b02=1)
DHW user max. setpoint (b02=2)
P09
DHW user max. setpoint (b02=3)
DHW user max. setpoint (b02=4)
Anti-inertia function temperature (b02=1)
No effect on adjustment (b02=2)
P10
Delivery temperature in DHW (b02=3)
Delivery temperature in DHW (b02=4)
Anti-inertia function Post-Circulation
(b02=1)
DHW Post-Circulation (b02=2)
P11
DHW Post-Circulation (b02=3)
DHW Post-Circulation (b02=4)
P12
Max. output in DHW
P13
Absolute min. power
P14
Post-Ventilation
CO2 limit Offset (b03=0)
No effect on adjustment (b03=1)
No effect on adjustment (b03=2)
P15
CO2 limit Offset (b03=3)
CO2 limit Offset (b03=4)
No effect on adjustment (b03=5)
P16
Exchanger protection activation
Modulating pump max. speed - absolute
P17
(optional)
Modulating pump max. speed - post circu-
P18
lation (optional)
Solar deactivation temperature (b02=1)
Solar deactivation temperature (b02=2)
P19
No effect on adjustment (b02=3)
No effect on adjustment (b02=4)
Solar ignition temperature (b02=1)
Solar ignition temperature (b02=2)
P20
No effect on adjustment (b02=3)
No effect on adjustment (b02=4)
Solar standby time (b02=1)
Solar standby time (b02=2)
P21
No effect on adjustment (b02=3)
No effect on adjustment (b02=4)
P22
Min. fan rpm (Low NOx)
P23
Fan start speed (Low NOx)
Notes:
1.
Parameters with more than one description vary their function and/or range in rela-
tion to the setting of the parameter given in brackets.
2.
Parameters with more than one description are reset to the default value if the pa-
rameter given in brackets is modified.
3.
The Maximum Heating Power parameter can also be modified in Test Mode.
4.
If left at 0 the parameter Minimum fan rpm (for Low NOx versions only) does not en-
able the possibility to modify the preset rpm values for minimum and for fan start; if
set above 0, this possibility is enabled, therefore the values that will be set for the
parameter itself (P22) and for the next one (P23) will be used; while the settable
range of parameter P23 is limited (80-180), lower values between 1 and 79 can also
be set in P22: in such cases the software will always work with the real minimum
rpm, i.e. 800 rpm (which corresponds to the value 80 in the parameter).
Press the Reset button to return to the Service Menu. Press the Reset button for 20 sec-
onds to exit the card Service Menu, or exiting occurs automatically after 15 minutes.
DIVACONDENS D
Range
PLUS F 24
50-65°C
50-65°C
55
50-65°C
50-65°C
5-85°C
--
0
70-85°C
70-85°C
0-10 Seconds
0-60 Seconds
30
0-60 Seconds
0-60 Seconds
0-100%
100
0-100%
0
0=Default
0
1=50 seconds
0 (Minimum)
30 (Maximum)
--
--
0 (Minimum)
20
30 (Maximum)
0 (Minimum)
30 (Maximum)
--
0=No F43
10
1-15=1-15°C/second
0-100% not working.Always at 100% in
100
this model
0-100% not working.Always at 100% in
60
this model
0÷20°C
0÷20°C
10
--
--
0÷20°C
0÷20°C
10
--
--
0-20 seconds
0-20 seconds
10
--
--
0=rpm preset,
0 (rpm/10)
1-120 (rpm/10)
80-180 (rpm/10)
120 (rpm/10)
cod. 3541P650 - Rev. 03 - 09/2018
"In" - Information Menu
9 pieces of information are available.
Press the Heating buttons to scroll the list of information in increasing or decreasing or-
der. Press the DHW buttons to display the value.
Contents
Description
t01
NTC Heating sensor (°C)
t02
NTC Safety sensor (°C)
t03
NTC DHW sensor (°C)
t04
NTC External sensor (°C)
L05
Actual burner power (%)
F06
Actual Flame resistance (kOhm)
St07
Fan step (Number)
F08
Actual DHW drawing (L min/10)
PP09
Actual modulating pump speed (%)
Notes:
1.
In case of damaged sensor, the card displays hyphens.
Press the Reset button to return to the Service Menu. Press the Reset button for 20 sec-
onds to exit the card Service Menu or exiting occurs automatically after 15 minutes.
"Hi" - History Menu
The card can store the last 11 faults: the History datum item H1: represents the most re-
cent fault that occurred; the History datum item H10: represents the least recent fault that
occurred.
The codes of the faults saved are also displayed in the corresponding menu of the Re-
mote Timer Control.
Press the Heating buttons to scroll the list of faults in increasing or decreasing order.
Press the DHW buttons to display the value.
Press the Reset button to return to the Service Menu. Press the Reset button for 20 sec-
onds to exit the card Service Menu, or exiting occurs automatically after 15 minutes.
"rE" - History Reset
Press the Eco/Comfort button for 3 seconds to delete all the faults stored in the History
Menu: the card will automatically exit the Service Menu, in order to confirm the operation.
Press the Reset button for 20 seconds to exit the card Service Menu, or exiting occurs
automatically after 15 minutes.
4.2 Commissioning
Before lighting the boiler
•
Check the seal of the gas system.
•
Check correct prefilling of the expansion tank.
•
Fill the water system and make sure all air contained in the boiler and the system
has been vented.
•
Make sure there are no water leaks in the system, DHW circuits, connections or boil-
er.
•
Check correct connection of the electrical system and efficiency of the earthing sys-
tem.
•
Make sure the gas pressure for heating is that required.
•
Make sure there are no flammable liquids or materials in the immediate vicinity of
the boiler
B
IF THE ABOVE INSTRUCTIONS ARE NOT OBSERVED THERE MAY BE
RISK OF SUFFOCATION OR POISONING DUE TO GAS OR FUMES ES-
CAPING; DANGER OF FIRE OR EXPLOSION. ALSO, THERE MAY BE A
RISK OF ELECTRIC SHOCK OR FLOODING THE ROOM.
Checks during operation
•
Switch the unit on.
•
Check the tightness of the fuel circuit and water systems.
•
Check the efficiency of the flue and air/fume ducts while the boiler is working.
•
Make sure the water is circulating properly between the boiler and the systems.
•
Make sure the gas valve modulates correctly in the heating and domestic hot water
production stages.
•
Check correct boiler lighting by performing various tests, turning it on and off with
the room thermostat or remote control.
•
Make sure the fuel consumption indicated on the meter matches that given in the
technical data table in cap. 5.
•
Make sure that with no demand for heating, the burner lights correctly on opening a
hot water tap. Check that in heating mode, on opening a hot water tap, the heating
circulating pump stops and there is regular production of hot water.
•
Make sure the parameters are programmed correctly and carry out any required
customisation (compensation curve, power, temperatures, etc.).
Range
between 05 and 125°C
between 05 and 125°C
between 05 and 125°C
between -30 and 70°C (negative values flash)Without NTC =
--
00%=Min., 100%=Max.
00-99 kOhm (-- = burner off)
0=Off, 1=Min, 2=Med, 3=Max
L min/10 over 99 flashing 3 figures
00-100% not working in this model
EN