WIRING

3

Wire the KPR2000.

Wire Insulation Color
Red
Black
Pink
Blue
Purple
Orange
Green
White
Pink
Yellow
Gray
Brown

WIRING EXAMPLES:

Gate/Door Operator or Fail-Secure Strike
Normally Open
External Alarm
(1 Amp Maximum)
Networking Two KPR2000 Units or Connecting to an Access Control System
External Alarm
(1 Amp Maximum)
Wiring Function
Basic Stand Alone Wiring
Power +
Power -
Power -
Relay NO
Relay Common
Relay NC
Pass-Through Wiring (Wiegand Master and Remote)
Data 0
Data 1
Ground
Advanced Input and Output Features
REX
Alarm Output
Contact Input
Install a 1N4007 or
equivalent diode.
KPR2000
Blue
Purple
Common
Red
Gray
Pink
Black
Install a 1N4007 or
equivalent diode.
Normally Open
KPR2000 Stand-Alone
Blue
Purple
Common
Red
Gray
Black
Pink
12~24 Volts DC Regulated Power Input
12~24 Volts DC Regulated Power Input
Ground Conductor
Normally Open Relay Output (Install diode provided)
Common Connection for Relay Output
Normally Closed Relay Output (Install diode provided)
Wiegand Output (Pass-through)/Input (Stand Alone) Data 0
Wiegand Output (Pass-through)/Input (Stand Alone) Data 1
Connect to ground to ensure proper alarm output operation
Request To Exit (REX) Input
Negative contact for Alarm
Door/Gate Contact Input (Normally Closed)
Magnetic Lock or Fail-Safe Strike
External Alarm
(1 Amp Maximum)
KPR2000 Stand-Alone
(Master Unit)
(Remote Unit)
Green (Data 0)
White (Data 1)
Pink (must connect for ground reference)
Maximum of 500 feet (152.4 m)
4
Notes
Install a 1N4007 or
equivalent diode.
Normally Closed
Orange
Purple
Common
Red
Gray
Pink
Black
Red
Black
Pink
KPR2000