PROBLEM
NO DISPLAY/SPA
• Spa is unplugged or off.
CONTROL UNIT
• Control panel cable plug loose.
DOES NOT WORK
• Power failure.
• RCD tripped.
• RCD broken.
HOUSEHOLD
• Circuit breaker under rated.
CIRCUIT BREAKER
• Overloaded circuit breaker.
TRIPPED
• An electrical fault in the line.
NOT HEATING
• Temperature set too low.
PROPERLY
• Dirty fi lter cartridge.
• Water temperature decreasing during
heater STANDBY mode.
• Heating element failed.
JET FUNCTION
• Jet pump is too hot.
DOES NOT WORK
JETS OUTPUT ARE
• Low water level.
WEAK
• Obstruction in the suction inlet inside
the tub.
• Jet nozzles clogged or dirty.
• Jet nozzles plumbing pipes damaged.
JET AIR CONTROL
• Jet nozzles clogged or dirty.
KNOB NOT
• Control panel jet airfl ow hose loose or
WORKING
damaged.
• Jet airfl ow plumbing inside the spa tub
damaged.
FILTRATION PUMP
• Dirty fi lter cartridge.
NOT WORKING
• Filtration inlet and/or outlet clogged.
• Filter pump motor failed.
WATER NOT CLEAN • Cartridge assembly not properly
attached.
• Insuffi cient fi ltering time.
• Dirty fi lter cartridge.
• Improper water maintenance.
• Filtration inlet and outlet clogged.
PUMP
• One characteristic of PVC is that
CONNECTORS ARE
it changes shape, which is normal.
NOT LEVEL
WITH THE SPA
CONNECTORS
S AVE THESE INSTRUCTIONS
(264IO) SPA (JET + BUBBLE) ENGLISH 7.5" X 10.3" PANTONE 295U 11/21/2014
TROUBLESHOOTING
CAUSE
SOLUTION
• Ensure the spa is plugged and switched on.
• Ensure the control panel cable plug is fi rmly
attached to the control base receptacle.
• Check power source.
• Reset the RCD.
• Contact Intex Service Center.
• Ensure correct circuit breaker rating.
• Provide a dedicated circuit breaker feeding the
spa electrical outlet only.
• Contact a qualify electrician to correct the
electrical fault.
• Increase the temperature and attach the spa
cover.
• Clean or replace the fi lter cartridge in time.
• If heater is in STANDBY mode, press the fl ame
button twice to heat up the water to the set
temperature.
• Contact Intex Service Center.
• Turn off and unplug the spa. Let it cool down and
restart all over again.
• If problem persists contact Intex Service Center.
• Add water between MIN and MAX level.
• Ensure suction inlet is not covered or blocked.
• Clean any dirt inside the jet nozzles.
• Contact Intex Service Center.
• Clean any dirt inside the jet nozzles.
• Ensure the jet air hose in the control panel (3)
is not damaged and securely attached. Replace
if needed.
• Contact Intex Service Center.
• Clean or replace the fi lter cartridge in time.
• Check and clean fi ltration inlet and outlet
regularly.
• Contact Intex Service Center.
• Ensure the cartridge assembly is properly
attached.
• Increase fi ltration time.
• Clean or replace the fi lter cartridge in time.
• Keep the spa water properly sanitized. Refer to
the chemical manufacturer's instructions.
• Check and clean fi ltration inlet and outlet
regularly.
• Elevate the pump with wood or another type of
insulated material to bring the pump's connectors
level with the spa's connectors.
264