Installation
instructions
'I
2
3
4
5
3-wire connections plus separate grounding
connector
For use where [ocam codes do not permit
grounding
through
the Neutral
wire.
Use approved
3-wire Power Supply Cord or a 3-wire CaMe for Direct Wiring as described on page 23.
A separate I OAWG copper grounding
wire is required.
Remove the terminal
block cover plate.
insert the power supply cable with a UL listed strain relief through the hole provided in the cabinet
near the terminal
block, Do not tighten
strain relief screw until wiring connections
are complete.
Note: a strain relief must be used.
strain relief
clamp sections
((
strain re[i_
screws
Fig.27 Inserting the power cord
Remove center terminal
block screw.
Remove appliance
ground [ink by removing
the ground connector
screw (Green screw).
Connect a separate copper ground wire (green with yellow
stripe) using the ground connector
screw (Green screw). Make sure a ring terminal
is used when connecting
the ground
wire and that
the wire is firmly secured to an adequate grounding
path.
Note: If the appliance
is
moved back to a 3-wire
installation
the ground
link must be refitted,
7
5
Remove
link
Fig,28 Connecting
the wires
6
Connect the neutral wire (center) of the power supply cord to the center terminal
screw of the
terminal
block. Tighten
screw.
7
Connect the other wires to the upper and lower terminal
block screws marked with the letter L
Tighten
screws.
8
Refit terminal
block cover by inserting
the two tabs first on the rear panel of the dryer and secure
cover with securing screw.
9
Tighten
strain relief screws.
S
i
9
It is recommended
that a qualified
electrician
1 Fig,29 Refitting
terminal
determine
that the ground
path is adequate
I
blockand
tightening
screws