Maintenance and Fault Repair
8.10

Fault repair

Fault
Cause
Machine won't run Plug not plugged in
Machine is switched off
Seal seam opaque
Sealing time too long
and blistered
Seal seam thin and
Sealing time too short
lacerated
No seal seam
Sealing wire broken
Fouling of the sealing pads 
Deterioration in
seal seam quality
Teflon strip worn
Silicone rubber worn
Sealing cylinder stiff
Poor vacuum in
Bag not sealed
the bag
Sharp edges pierce the bag 
Bag too big for the product 
Bag opening contaminated 
Sealing cylinders are
jamming and sealing pad
has come out
Operating Instructions- Translation
Solution
Plug in the plug
Switch master switch to 1
Reduce sealing time
Increase sealing time
Replace the sealing wire
Clean the bottom of the sealing pads
(brass contact surfaces)
Replace the Teflon strip
Replace the silicone rubber
Replace the Teflon strip
Replace the silicone rubber
Lubricate the pump rod
Use another bag
Use a stronger bag
Modify the bag size to the product
Use a new bag and keep the bag
opening clean
Arrange for the sealing cylinders and
the pressure valve to be checked by
technical staff
Fault
Cause
Poor vacuum in
Poor pump power from the
the chamber
vacuum pump
Cover seal faulty
No vacuum in the
GreenVac fitting is still
chamber
connected
Pump doesn't work
The cover not
Loss of pressure in the
comes open
pneumatic springs at the
cover
Pneumatic spring is
expanded
Build-up of smoke Oil moistened exhaust filter
element
During operation with the gassing option:
Fault
Cause
No gas in the bag
Gassing is switched off
Shut-off valves on gas
bottle or bottle pressure
reducer are closed
Gas nozzles are not in the
bag opening
Gas bottle empty
Powder-like
The propulsion flow of the
products are
gas is too high
whirled up by the
flow of gas
19 04 249 - 01.01.2012
Solution
Check the oil level
Replace the cover seal
Remove the GreenVac fitting as
chamber mode is disabled in
GreenVac mode.
Let the pump be checked by a trained
person
Replace the pneumatic springs
Open the cover up to its limit stop, the
pneumatic spring is thereby once again
contracted
Switch off the machine
Unplug the plug from the socket
Replace the exhaust filter element
Solution
Press the GAS ON/OFF button, the
display is illuminated when gassing is
switched on
Open the shut-off valves
Pull the opening of the bag over the
gas nozzles
Replace the gas bottle
Adjust the propulsion flow using the
shut-off valve on the bottle pressure
reducer